19-217/BHC-YL2M2TY/3T
Reliability Test Items And Conditions
The reliability of products shall be satisfied with items listed below.
Confidence level:90%
LTPD:10%
No.
Items
Test
Sample
Test Condition
Ac/Re
Hours/Cycles Size
Temp. : 260℃±5℃
1 Reflow Soldering
Min. 5sec.
6 Min. 22 PCS. 0/1
H : +100℃ 15min
2 Temperature Cycle
∫ 5 min
300 Cycles 22 PCS. 0/1
L : -40℃ 15min
H : +100℃ 5min
3
Thermal Shock
∫ 10 sec
300 Cycles 22 PCS. 0/1
L : -10℃ 5min
High Temperature
4
Storage
5
Low Temperature
Storage
Temp. : 100℃
Temp. : -40℃
1000 Hrs. 22 PCS. 0/1
1000 Hrs. 22 PCS. 0/1
6 DC Operating Life
IF = 20 mA
1000 Hrs. 22 PCS. 0/1
7 High Temperature /
High Humidity
85℃/ 85% RH
1000 Hrs. 22 PCS. 0/1
Everlight Electronics Co., Ltd.
Device No: DSE-0001439
http://www.everlight.com
Prepared date: 8-May-2009
Rev.2
Page: 8 of 10
Prepared by: Qiang yafang