AC Characteristics
Table 4. AC Characteristics(1)
2.7-volt
5.0-volt
Symbol
Parameter
Min
Max
Min
Max
Units
fSCL
Clock Frequency, SCL
400
1000
kHz
tLOW
Clock Pulse Width Low
1.3
0.4
µs
tHIGH
Clock Pulse Width High
0.6
0.4
µs
tAA
Clock Low to Data Out Valid
0.05
0.9
0.05
0.55
µs
Time the bus must be free before a new
tBUF
transmission can start(2)
1.3
0.5
µs
tHD.STA
Start Hold Time
0.6
0.25
µs
tSU.STA
Start Set-up Time
0.6
0.25
µs
tHD.DAT
Data In Hold Time
0
0
µs
tSU.DAT
tR
tF
Data In Set-up Time
Inputs Rise Time(2)
Inputs Fall Time(2)
100
100
ns
0.3
0.3
µs
300
100
ns
tSU.STO
Stop Set-up Time
0.6
0.25
µs
tDH
Data Out Hold Time
50
50
ns
tWR
Endurance(2)
Write Cycle Time
25°C, Page Mode
5
5
ms
1M
1M
Write Cycles
Notes:
1. Applicable over recommended operating range from TA = 0°C to +70°C, VCC = +2.7V to +5.5V, CL = 100 pF (unless other-
wise noted). Test conditions are listed in Note 3.
2. This parameter is characterized and is not 100% tested.
3. AC measurement conditions:
RL (connects to VCC): 1.3 kΩ (2.7V, 5V),
Input pulse voltages: 0.3VCC to 0.7VCC
Input rise and fall times: ≤ 50ns
Input and output timing reference voltages: 0.5VCC
4 AT24C128SC/AT24C256SC
1661B–SEEPR–04/04