12
Option Specifications
Clamp On Sensors
9694
Cord length: 3 m (9.84 ft)
Appearance
9660
Cord length: 3 m (9.84 ft)
9661
Cord length: 3 m (9.84 ft)
9669
Cord length: 3 m (9.84 ft)
CAT III 300V
Primary current rating
5A AC
CAT III 300V
100 A AC
CAT III 600V
500 A AC
Output voltage
10 mV/A AC
1 mV/A AC
1 mV/A AC
Accuracy Amplitude
(45 to 66 Hz) Phase
±0.3% rdg. ±0.02% f.s. ±0.3% rdg. ±0.02% f.s. ±0.3% rdg. ±0.01% f.s.
±2˚ or less
±1˚ or less (±1.3˚ for 90 A or more)
±0.5˚ or less
Frequency characteristic
±1.0% or less for 66 Hz to 5 kHz (deviation from specified accuracy)
Effect of external magnetic field
Corresponding to 0.1 A or less (with magnetic field of 400 A/m AC)
Effect of conductor position
±0.5% or less
Maximum rated voltage to earth 300 Vrms (insulated conductor) 300 Vrms (insulated conductor) 600 Vrms (insulated conductor)
Maximum allowable input (45 to 66 Hz)
50 A continuous
130 A continuous
550 A continuous
Measurable conductor diameter φ15 mm (0.59") or less
φ15 mm (0.59") or less
φ46 mm (1.81") or less
Dimensions and weight
46W (1.81") × 135H (5.31") × 46W (1.81") × 135H (5.31") × 77W (3.03") × 151H (5.94") ×
21D (0.83") mm, 230 g (8.1 oz.) 21D (0.83") mm, 230 g (8.1 oz.) 42D (1.65") mm, 360g (12.7 oz.)
CAT III 600V
1000 A AC
0.5 mV/A AC
±1.0% rdg. ±0.01% f.s.
±1˚ or less
±2.0% or less for 66 Hz to 5 kHz (deviation from specified accuracy)
Corresponding to 1 A or less (with magnetic field of 400 A/m AC)
±1.5% or less
600 Vrms (insulated conductor)
1000 A continuous
φ55 mm (2.17") or less, 80 (3.15") × 20 (0.79") mm busbar
99.5W (3.92") × 188H (7.40") × 42D (1.65") mm,
590g (20.8 oz.)
Clamp On Sensor
Appearance
9667
Cord length
Sensor to circuit: 2 m (6.56 ft)
Circuit to connector: 1 m (3.28 ft)
CAT III 1000V
Primary current rating
500 A AC, 5000 A
Output voltage
500 mV AC f.s.
Accuracy Amplitude
±2.0% rdg. ±1.5 mV (for input 10% or more of the range)
(45 to 66 Hz) Phase
±1˚ or less
Frequency characteristic
±3 dB or less for 10 Hz to 20 kHz (deviation from specified accuracy)
Effect of external magnetic field Corresponding to 5 A, 7.5 A max. (with magnetic field of 400 A/m AC)
Effect of conductor position
±3.0% or less
Maximum rated voltage to earth
1000 Vrms (insulated conductor)
Maximum allowable input (45 to 66 Hz)
10000 A continuous
Measurable conductor diameter
φ254 mm (10") or less
Dimensions and weight
Power supply
Sensor length: 910 mm (2.99 ft), 240 g (8.5 oz.),
Circuit: 57W (2.24") × 86H (3.39") × 30D (1.18") mm, 140 g (4.9 oz.)
LR03 alkaline battery × 4 (continuous operation max. 168 hours) or
9445 AC ADAPTER(optional)
9290-10 CLAMP-ON ADAPTER
Cord length : 3 m (9.84 ft)
Up to 1500 A AC, CT ratio : 10:1
Measurable conductor diameter :
φ55 mm (2.17"), width : 80 mm (2.17") bus bar
Standard accessories
9458 AC ADAPTER
100 to 240 V AC, 1.2 A
50/60 Hz
9339 CARRYING CASE
(soft case)
9340 CARRYING CASE
(hard case)
104W (4.09") × 51H (2.01") ×
18D (0.71") mm, 250 g (8.83 oz.)
9459 BATTERY PACK
450W (17.72") × 350H (13.78") × 200D
(7.87") mm, 3.0 kg (106.01 oz.)
380W (14.96") × 560H (22.05") × 260D
(10.24") mm, 6.3 kg (222.2 oz.)
7.2 V DC, 2700 mAh
9670 PRINTER option components
The 9671 AC ADAPTER should be purchased along with the 9670 PRINTER.
Also, the 9638 RS-232C CONNECTION CABLE or RS-232C cable (9- to
25-pin crossover) is required to connect to the 3196.
A battery pack and battery charger to power the 9670 Printer are also available in
some countries. Please contact your HIOKI distributor for details.
9671 AC ADAPTER
100 to 240 VAC, 50/60 Hz
134W (5.28") × 70H (2.76") × 41D (1.61") mm
350 g (12.37 oz.)
Accessories
3196 POWER QUALITY ANALYZER
(9438-02 VOLTAGE MEASUREMENT CABLE (one each of red, yellow, blue
and gray, plus four black lines, Cord length: 3 m (9.84 ft), 9459 BATTERY PACK,
9458 AC ADAPTER, Strap, LAN connector cover, Input Cord Label, Operating
Manual (CD-R), Quick Start Manual)
By itself, the 3196 is only capable of voltage measurement. Purchase the optional
9660 or 9661 CLAMP-ON SENSOR for current and power measurement.
Standard combination example
For three-phase 3-wire (3P3W3M) and three-phase 4-wire measurements
Models 3196 + 9661 (500 A) × 3 + 9339 + PC card (128 MB)
Options
9660 CLAMP ON SENSOR (100 A AC) Voltage output type
9661 CLAMP ON SENSOR (500 A AC) Voltage output type
9667 FLEXIBLE CLAMP ON SENSOR (5000 A AC) Voltage output type
9445-02 AC ADAPTER (for the 9667, for America, Japan)
9445-03 AC ADAPTER (for the 9667, for Europe)
9669 CLAMP ON SENSOR (1000 A AC) Voltage output type
9694 CLAMP ON SENSOR (5 A AC) Voltage output type
9657-10 CLAMP ON LEAK SENSOR (5A AC with Model 3196) Voltage Output Type
9675 CLAMP ON LEAK SENSOR (5A AC with Model 3196) Voltage Output Type
9290-10 CLAMP ON ADAPTER
9264-01 WIRING ADAPTER (3P3W)
9264-02 WIRING ADAPTER (3P4W)
9438-02 VOLTAGE MEASUREMENT CABLE (standard accessory)
9459 BATTERY PACK (standard accessory)
9670
PRINTER (with one roll recording paper)
9671 AC ADAPTER (for 9670)
9237
RECORDING PAPER (80 mm (3.15") x 25 m (82.03 ft), 4 rolls, for 9670)
9638
RS-232C CABLE (1.5 m (4.92 ft), for printer connection)
9642
LAN CABLE (5m (16.41 ft), with straight and crossover connectors)
9339 CARRYING CASE (soft)
9340 CARRYING CASE (hard)
9624 PQA-HiVIEW (PC application software)
9624-10 PQA-HiVIEW PRO (PC application software)
9726
*Please select either USB or Parallel license Key.
PC CARD 128 M
9727 PC CARD 256 M
9728 PC CARD 512 M
Operating Manual (bound version)
XD112 GPS Box (including antenna and RS-232C cable)
DISTRIBUTED BY
HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
E-mail: os-com@hioki.co.jp
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
E-mail: hioki@hiokiusa.com
Shanghai Representative Office :
1704 Shanghai Times Square Office
93 Huaihai Zhong Road
Shanghai, 200021, P.R.China
TEL +86-21-6391-0090, 0092
FAX +86-21-6391-0360
E-mail: info@hioki.cn
All information correct as of Jan. 6, 2006. All specifications are subject to change without notice.
3196E7-61B-05P Printed in Japan
Share Link: GO URL

All Rights Reserved © qdatasheet.com  [ Privacy Policy ] [ Contact Us ]