12
Composition of options
Note: Product names appearing herein are trademarks or registered trademarks of various companies.
Install by inserting into the main unit. Can be replaced by user.
Note: Input cables are not supplied. Please purchase the
appropriate cable for the intended application.
Input modules
ANALOG UNIT 8936
VOLTAGE/TEMP UNIT 8937
FFT ANALOG UNIT 8938
STRAIN UNIT 8939
F/V UNIT 8940
(used with the 8841/8842, Ver. 2.10 or later)
4ch ANALOG UNIT 8946
(for the 8841 only, cannot use with the 8842.)
CHARGE UNIT 8947
(used with the 8841/8842, Ver. 2.20 or later)
Logic signal measurement
LOGIC PROBE 9320
4-channel type, for voltage/contact
signal ON/OFF detection
LOGIC PROBE 9321
4 isolated channels, ON/OFF detection
of AC/DC voltage
Current measurement * The 3274, 3275, and 3276 cannot be used for the F/V UNIT 8940
F/V UNIT 8940
9279 Not CE certified
Voltage measurement
CONNECTION CORD
9197
For high voltage (up to 500V)
DIFFERENTIAL PROBE 9322
For up to 2kV DC or 1kV AC, AC adapter
9418-15 required for operation.
AC ADAPTER 9418-15
For powering Differential probe 9322,
100 to 240V AC, 12V/2.5 A
POWER CORD
CONNECTION CORD
9198
For low voltage (up to 300V)
9324
Use to the 9322 from the logic terminal.
* Note that usage restrictions apply.
POWER CORD
9325
Use to the 9322 from the F/V UNIT 8940.
* Note that usage restrictions apply.
CONNECTION CORD 9217
Insulated BNC connectors at
both ends, and connects to
insulated BNC connectors
Not CE certified
PT 9303
Insulation transformer, 400V or
200V AC input, 10V AC output,
for AC power line measurement.
Not CE certified
CONNECTION CORD 9165
Metal BNC connectors at both
ends, and connects to metal
BNC connectors
CONVERSION ADAPTER 9199
Banana-to-BNC, use to connect to
insulation-BNC terminal on Input section
MEMORY HiCORDER 8841
* The MEMORY HiCORDER 8841 cannot operate alone. You
must install one or more optional input modules in the unit.
MEMORY HiCORDER 8842
* The MEMORY HiCORDER 8842 cannot operate alone. You
must install one or more optional input modules in the unit.
Current measurement
F/V UNIT 8940
9270, 9271
9272-10
9555-10
CONVERSION
CLAMP
CABLE 9318 (to connect
ON SENSOR
9270 - 9272
9270
aNnodt8C9E40c)ertifiedSMEoNdeSl O95R55-U10NisITreq9u5ire5d5to-1po0wer the Clamp-On
Sensors, except for connecting Clamp-On Sensor
5Hz to 50kHz response, up to 20A rms, 2V
Model 9270, 9271, 9272-10 to Model 8940, and
AC output
for signal output, Model 9217 Connection Cord is
CLAMP ON SENSOR 9271
5Hz to 50kHz response, up to 200A rms,
2V AC output
required to connect for input modules.
CLAMP ON PROBE 9018-10
Input from 10 to 500A, 40Hz to 3kHz for
0.2V AC output. BNC terminal
CLAMP ON SENSOR 9272-10
1Hz to 100kHz response, selectable 20 and
200A rms ranges, 2V AC output
CLAMP ON PROBE 9132-10
Input from 20 to 1000A, 40Hz to 1kHz for 0.2V
AC output. BNC terminal, Not CE certified.
CONVERSION CABLE 9318
to connect 9270/9271/9272 and 8940
CLAMP ON LEAK SENSOR 9657-10
For leak current only, 10A for rated current,
40Hz to 5kHz, output rate 100mV/A AC,
BNC terminal
9277
3273-50
CONVERSION CABLE 9318 (to connect 9277 - 9279 and 8940) 9278 CONVERSION CABLE 9319 (to connect 3273-50 and 8940)
UNIVERSAL CLAMP ON CT 9277 CLAMP ON PROBE 3273-50
Observe waveforms from DC to distorted DC to 50MHz wideband response,
AC. DC to 100kHz response, input 20A / mA-class current up to 30A rms
output 2V AC
CONVERSION CABLE 9319
to connect 3273-50 and 8940
UNIVERSAL CLAMP ON CT 9278
Observe waveforms from DC to distorted
AC. DC to 100kHz response, input 200A /
output 2V AC
CONNECTION CORD 9217
UNIVERSAL CLAMP ON CT 9279
Observe waveforms from DC to distorted
Cord has insulated BNC connectors
at both ends, and connects to the
9555-10 and input moduls.
AC. DC to 20kHz response, input 500A /
output 2V AC
CONVERSION CABLE 9318
to connect 9277/9278/9279 and 8940
SENSOR UNIT 9555-10
Model 9555-10 is required to power the Clamp-
On CTs, except for connecting Clamp-On CT
Model 9277/78/79 to Model 8940, and for
signal output, Model 9217 Connection Cord is
required to connect for input modules.
3274
3275
3273-50
3276
CLAMP ON PROBE 3273-50
DC to 50MHz wideband response,
mA-class current up to 30A rms
CLAMP ON PROBE 3274
DC to 10MHz wideband response,
mA-class current up to 150A rms
CLAMP ON PROBE 3275
DC to 2MHz wideband response,
mA-class current up to 500A rms
3272
3269
CLAMP ON PROBE 3276
DC to 100MHz wideband response,
mA-class current up to 30A rms
POWER SUPPLY 3272
Connect and power up to one Clamp-On Probes
to use in combination with voltage input modules
(up to two PROBEs restrictively)
POWER SUPPLY 3269
Connect and power up to four Clamp-On Probes
to use in combination with voltage input modules
Internal option
MEMORY BOARD 9608
Expands main unit memory by 4×, Must
specify when ordering: not user installable.
MO UNIT 9607
Discontinued
Supplied with
PC Card
PC CARD 128M 9726
adapter
(128 MB capacity)
PC Card Precaution
Use only PC Cards sold
by HIOKI. Compatibility
and performance are not
guaranteed for PC cards made
by other manufacturers. You
may be unable to read from or
save data to such cards.
PC CARD 256M 9727
(256 MB capacity)
PC CARD 512M 9728
(512 MB capacity)
PC CARD 1G 9729
(1 GB capacity)
Printing
RECORDING PAPER 9231
216 mm (8.50 in) × 30 m (98.43 ft),
6 rolls set
Communication
Not CE certified
DC POWER ADAPTER 9433
Supplies operating power in the range
10 to 28V DC.
CARRYING CASE 9397-01
(for 8841/8855 only)
With casters for convenient
transportation.
CARRYING CASE 9349
(for 8842 only)
With casters for convenient
transportation.
PAPER WINDER 220H
Paper width 70mm (2.75 in) to
220mm (8.66 in), using special-
purpose AC adapter
Not CE certified
RS-232C CARD 9557 GP-IB CARD 9558
PCMCIA-compliant
PCMCIA-compliant, cord
length: 2m (6.6ft)
LAN CARD
May not operate depending on the
environment. , 10BASE-T
LAN COMMUNICATOR 9333
LAN CABLE 9642
Application software to create a LAN
Supplied with cross conversion
cable, straight Ethernet cable,
length: 5m (16.4ft)
connection with Windows 95/98/Me, or
Windows NT 4.0/2000/XP.
WAVE PROCESSOR 9335
Data conversion, print functions, waveform
display, compatible with Windows 95/98/Me,
Windows NT 4.0/2000/XP, and Windows
Vista 32-bit type.
■ Combination example: 8841 (normal choice of the input unit, up to 200V AC direct input.)
Main unit Memory 8MW
4ch
8ch
Model number × quantity 8841×1 standard
8936×2
8936×4
Input cable
9198×4
9198×8
■ Combination example: 8842 (normal choice of the input unit, up to 200V AC direct input.)
Main unit Memory 8MW
4ch
8ch
Model number × quantity 8842×1 standard
8936×2
8936×4
Input cable
9198×4
9198×8
12ch
8936×6
9198×12
16ch
8936×8
9198×16
■ Combination example: 8841 (select an automotive input unit that can handle up to 30 V AC.)
Main unit Memory 8MW
Model number × quantity 8841×1 standard
Input cable
8ch
8946×2
9198×8
16ch
8946×4
9198×16
HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
E-mail: os-com@hioki.co.jp
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
E-mail: hioki@hiokiusa.com
HIOKI (Shanghai) Sales & Trading Co., Ltd. :
1904 Shanghai Times Square Office, 93 Huai Hai Zhong Road
DISTRIBUTED BY
Shanghai, P.R.China POSTCODE: 200021
TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360
E-mail: info-sh@hioki.cn
Beijing Office :
A-2602 Freetown, 58 Dong San Huan Nan Road
Beijing, P.R.China POSTCODE: 100022
TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090
E-mail: info-bj@hioki.cn
Guangzhou Office :
Room 303, Profit Plaza, No.76, West Huangpu Road
Guangzhou, P.R.China POSTCODE: 510623
TEL +86-20-38392673/2676 FAX +86-20-38392679
E-mail: info-gz@hioki.cn
All information correct as of Sep. 11, 2007. All specifications are subject to change without notice.
8841E10-79M-00P Printed in Japan