A1184
Standard Two-Wire Field-Programmable Chopper-Stabilized Unipolar Hall Effect Switch
ELECTRICAL CHARACTERISTICS over the operating voltage and temperature range, unless otherwise specified
Characteristic
Symbol
Test Conditions
Min.
Typ.
Max. Units
Supply Voltage1
Supply Current2
Supply Zener Clamp Voltage
Supply Zener Clamp Current3
VCC
ICC(L)
ICC(H)
VZ(supply)
IZ(supply)
Device powered on
B <BRP
B >BOP
ICC = ICC(L)(max) + 3 mA; TA = 25°C
VZ(supply) = 28 V
3.5
–
24
V
5
–
6.9
mA
12
–
17
mA
28
–
40
V
–
–
9.9
mA
Reverse Supply Current
Output Slew Rate4
IRCC
VRCC = –18 V
–
No bypass capacitor; capacitance of the
di/dt oscilloscope performing the measurement
–
= 20 pF
–
–1.6
mA
36
–
mA/μs
Chopping Frequency
fC
–
200
–
kHz
Power-On Time5
ton
After factory trimming; with and without
bypass capacitor (CBYP = 0.01 μF)
–
–
25
μs
Power-On State6,7
POS
ton ≤ ton(max); VCC slew rate ≥ 25 mV/μs
–
HIGH
–
–
1VCC represents the generated voltage between the VCC pin and the GND pin.
2Relative values of B use the algebraic convention, where positive values indicate south magnetic polarity, and negative values indicate north magnetic
polarity; therefore greater B values indicate a stronger south polarity field (or a weaker north polarity field, if present).
3IZSUPPLY(max) = ICCL(max) + 3 mA.
4Measured without bypass capacitor between VCC and GND. Use of a bypass capacitor results in slower current change.
5Measured with and without bypass capacitor of 0.01 μF. Adding a larger bypass capacitor causes longer Power-On Time.
6POS is defined as true only with a VCC slew rate of 25 mV / μs or greater. Operation with a VCC slew rate less than 25 mV / μs can permanently harm
device performance.
7POS is undefined for t > ton or BRP < B < BOP .
MAGNETIC CHARACTERISTICS1 over the operating voltage and temperature range, unless otherwise specified
Characteristic
Symbol
Test Conditions
Min.
Typ.
Max. Units
Programmable Operate Point Range BOPrange ICC = ICC(H)
300
–
600
G
Initial Operate Point Range
Switchpoint Step Size2
Number of Programming Bits
BOPinit
BRES
–
VCC = 12 V
VCC = 5 V, TA = 25°C
Switchpoint setting
Programming locking
–
262
300
G
8
16
24
G
–
5
–
Bit
–
1
–
Bit
Temperature Drift of BOP
ΔBOP
–
–
±20
G
Hysteresis
BHYS BHYS = BOP – BRP
5
15
30
G
1Relative values of B use the algebraic convention, where positive values indicate south magnetic polarity, and negative values indicate north magnetic
polarity; therefore greater B values indicate a stronger south polarity field (or a weaker north polarity field, if present).
2The range of values specified for BRES is a maximum, derived from the cumulative programming bit errors.
A1184-DS, Rev. 2
Allegro MicroSystems, Inc.
3
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000