1600
1400
IF = 3 mA, VCC = 3.3 V
IF = 10 mA
1200
IF = 3 mA
1000
800
tPLH
600
400
tPHL
200
01
RL - LOAD RESISTANCE - kΩ
Figure 9. Typical Propagation Delay vs. Load Resistance
1000
900
IF = 3 mA, VCC = 5 V
800
IF = 10 mA
IF = 3 mA
700
600
500
400
tPLH
300
tPHL
200
100
10
01
10
RL - LOAD RESISTANCE - kΩ
Figure 10. Typical Propagation Delay vs. Load Resistance
2600
2400 IF = 3 mA, VCC = 24 V
2200 RL = 10 kΩ, TA = 25°C
2000
1800
1600
1400
1200
tPLH
1000
tPHL
800
600
400
200
00
100
200
300
400
500
CL - LOAD CAPACITANCE - pF
2600
2400 IF = 3 mA, VCC = 24 V
2200 RL = 14.8 kΩ, TA = 25°C
2000
1800
1600
1400
tPHL
1200
1000
tPLH
800
600
400
200
0
0
100
200
300
400
500
CL - LOAD CAPACITANCE - pF
Figure 11a. Typical Propagation delay vs. Load Capacitance (ACPL-M50L)
Figure 11b. Typical Propagation delay vs. Load Capacitance
(ACPL-054L/W50L/K54L)
2500
2500
IF = 3 mA
IF = 3 mA
2000
RL = 10 kΩ
2000
RL = 14.8 kΩ
TA = 25°C
TA = 25°C
1500
1500
1000
500
08
tPLH
tPHL
10 12 14 16 18 20 22 24
VCC - SUPPLY VOLTAGE - V
Figure 12a. Typical Propagation Delay vs. Supply Voltage (ACPL-M50L)
1000
500
tPLH
tPHL
0 8 10 12 14 16 18 20
VCC - SUPPLY VOLTAGE - V
Figure 12b. Typical Propagation Delay vs. Supply Voltage
(ACPL-054L/W50L/K54L)
22 24
14