350
TPHL
300
TPLH
250
200
150
IF = 7 mA
100
VCC = 30 V, VEE = 0 V
Rg = 10 Ω, Cg = 25 nF
50
DUTY CYCLE = 50%
f = 20 kHz
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100
TA - TEMPERATURE - °C
Figure 19. Propagation delay vs. temperature.
300
250
200
TPLH
TPHL
150
100
VCC = 30 V, VEE = 0 V
IF = 7 mA, TA = 25°C
50
Cg = 25 nF
DUTY CYCLE = 50%
f = 20 kHz
0
0 5 10 15 20 25 30 35 40 45 50
Rg - SERIES LOAD RESISTANCE - Ω
Figure 20. Propagation delay vs. Rg.
300
100
250
200
TPLH
TPHL
10
150
100
VCC = 30 V, VEE = 0 V
IF = 7 mA, TA = 25°C
50
Rg = 10 Ω
DUTY CYCLE = 50%
f = 20 kHz
0
0 5 10 15 20 25 30 35 40 45 50
Cg - LOAD CAPACITANCE - nF
1
0.1
1.4
1.45
1.5
1.55
1.6
1.65
VF - FORWARD VOLTAGE - VOLTS
Figure 21. Propagation delay vs. Cg.
Figure 22. Input current vs. forward voltage.
11