ACPL-M50L, ACPL-054L, ACPL-W50L, ACPL-K54L
Data Sheet
Package Characteristics
All typical at TA = 25°C
Table 10 Package Characteristics
Parameter
Symbol
Input-Output Momentary Withstand VISO
Voltagea,b
Input-Output Resistancea
RI-O
Input-Output Capacitancea
CI-O
Input-Input Insulation Leakage
II-I
Current[3]
Input-Input Resistancec
RI-I
Input-Input Capacitancec
CI-I
Part Number
ACPL-M50L/054L
ACPL-W50L/K54L
Min.
3750
5000
—
—
—
Typ.
—
—
1014
0.6
0.005
Max.
—
—
—
—
—
Units
Test Conditions
Vrms RH ≤ 50%, t = 1 min., TA = 25°C
VI-O = 500 Vdc
pF f = 1 MHz, TA = 25°C
μA RH ≤ 45%, t = 5 s, VI-I = 500Vdc
— 1011 —
—
0.25
—
pF f = 1 MHz
a. Device considered a two terminal device: pins 1 and 3 shorted together and pins 4, 5 and 6 shorted together for ACPL-M50L, pins 1, 2, 3 and 4 shorted together
and pins 5, 6, 7 and 8 shorted together for ACPL-054L/K54L, pins 1, 2 and 3 shorted together and pins 4, 5 and 6 shorted together for ACPL-W50L.
b. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage ≥ 4500 VRMS for 1 second for ACPL-M50L/054L and
≥ 6000 VRMS for 1 second for ACPL-W50L/K54L (leakage detection current limit, II-O ≤ 5mA)..
c. Measured between pins 1 and 2 shorted together and pins 3 and 4 shorted together for ACPL-054L/K54L.
Broadcom
- 13 -