Qdatasheet_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

ACPM-7813 View Datasheet(PDF) - HP => Agilent Technologies

Part Name
Description
MFG CO.
ACPM-7813
HP
HP => Agilent Technologies HP
'ACPM-7813' PDF : 21 Pages View PDF
ACPR Measurement Method
Adjacent-channel power ratio
(ACPR) is used to characterize
the distortion of power amplifiers
and other subsystems for their
tendency to cause interference
with neighboring radio channels
or systems. The ACPR measure-
ment often is specified as the
ratio of the power spectral
density (PSD) of the CDMA main
channel to the PSD measured at
several offset frequencies. For the
Cellular band (824 ~ 849 MHz
transmitter channel), the two
offsets are at ±885 kHz and
±1.98 MHz and the measurement
resolution bandwidth specified is
30 kHz. These offsets are at
±1.25 MHz and ±1.98 MHz for the
PCS band (1850 ~ 1910 MHz
transmitter channel).
0
-10
-20
-30
30 kHz
-40
-50
-60
-70
-80
1.23 MHz
30 kHz
30 kHz
1st ACPR-L
1st ACPR-U
Offset frequency
2nd ACPR-L
= 1.98 MHz
2nd ACPR-U
= 1.98 MHz
FREQUENCY (MHz)
Figure 18. CDMA Adjacent-Channel Power Ratio Measurement.
1st ACPR (dBc)
2nd ACPR (dBc)
30 kHz
14