ACS706ELC-05C
OPERATING CHARACTERISTICS
Characteristic
Symbol
Test Conditions
Min. Typ. Max. Units
ELECTRICAL CHARACTERISTICS, over operating ambient temperature range unless otherwise specified
Optimized Accuracy Range
Linear Sensing Range
Supply Voltage
Supply Current
Output Resistance
Output Capacitance Load
Output Resistive Load
Primary Conductor Resistance
RMS Isolation Voltage
DC Isolation Voltage
IP
IR
VCC
ICC
ROUT
CLOAD
RLOAD
RPRIMARY
VISORMS
VISODC
VCC = 5.0 V, output open
IOUT = 1.2 mA
VOUT to GND
VOUT to GND
TA = 25°C
Pins 1-4 and 5-8; 60 Hz, 1 minute
–5
–
5
A
–15
–
15
A
4.5
5.0
5.5
V
5
8
10
mA
–
1
2
Ω
–
–
10
nF
4.7
–
–
kΩ
–
1.5
–
mΩ
1600 2500
–
V
–
5000
–
V
PERFORMANCE CHARACTERISTICS, over operating ambient temperature range, unless otherwise specified
Propagation Time
Response Time
Rise Time
Frequency Bandwidth
Sensitivity
Noise
Linearity
Symmetry
Zero Current Output Voltage
Electrical Offset Voltage
tPROP
tRESPONSE
tr
f
Sens
VNOISE
ELIN
ESYM
VOUT(Q)
VOE
IP =±5 A, TA = 25°C
IP =±5 A, TA = 25°C
IP =±5 A, TA = 25°C
–3 dB, TA = 25°C; IP is 10 A peak-to-peak; no external filter
Over full range of IP , IP applied for 5 ms; TA = 25°C
Over full range of IP , IP applied for 5 ms
Peak-to-peak, TA = 25°C, no external filter
Root Mean Square, TA = 25°C, no external filter
Over full range of IP , IP applied for 5 ms
Over full range of IP , IP applied for 5 ms
IP = 0 A, TA = 25°C
IP = 0 A, TA = 25°C
IP = 0 A
–
3.15
–
μs
–
6
–
μs
–
7.45
–
μs
–
50
–
kHz
–
133
–
mV/A
124
–
142 mV/A
–
90
–
mV
–
16
–
mV
–
±1
±4.7
%
98
100 104.5
%
–
VCC / 2
–
V
–15
–
15
mV
–65
–
65
mV
Magnetic Offset Error
IERROM IP = 0 A, after excursion of 5 A
–
±0.01 ±0.05
A
Total Output Error1
ETOT
IP =±5 A, IP applied for 5 ms;TA = 25°C
IP = ±5 A, IP applied for 5 ms
THERMAL CHARACTERISTICS2,3, TA = –40°C to 125°C, VCC = 5 V unless otherwise specified
–
±1.5
–
%
–
–
±12.5
%
–
Value
–
Units
Junction-to-Lead Thermal
Resistance
Mounted on the Allegro ASEK 70x evaluation board; additional
RθJL information about reference boards and tests is available on the
–
5
–
°C/W
Allegro Web site
Junction-to-Ambient Thermal
Resistance
RθJA
Mounted on the Allegro ASEK 70x evaluation board; additional
information about reference boards and tests is available on the
Allegro Web site
–
41
–
°C/W
1Percentage of IP, with IP = 5 A. Output filtered. Up to a 2.0% shift in ETOT may be observed at end-of-life for this device.
2 The Allegro evaluation board has 1500 mm2 of 2 oz. copper on each side, connected to pins 1 and 2, and to pins 3 and 4, with thermal vias connect-
ing the layers. Performance values include the power consumed by the PWB. Further details on the board are available from the ACS704 Frequently
Asked Questions document on our website. Further information about board design and thermal performance also can be found on pages 16 and 17 of
this datasheet.
3RθJA values shown in this table are typical values, measured on the Allegro evaluation board. The actual thermal performance depends on the board
design, the airflow in the system, and thermal interactions between the sensor and surrounding components through the PCB and the ambient air. To
improve thermal performance, see our applications material on the Allegro Web site.
ACS706ELC05C-DS, Rev. 1
3
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000
www.allegromicro.com