ACS711
Hall Effect Linear Current Sensor with Overcurrent
Fault Output for < 100 V Isolation Applications
COMMON OPERATING CHARACTERISTICS over full range of TA and VCC = 3.3 V, unless otherwise specified
Characteristic
Symbol
Test Conditions
Min. Typ.
Max. Units
ELECTRICAL CHARACTERISTICS
Supply Voltage1
Supply Current
Output Capacitance Load
Output Resistive Load
Primary Conductor
Resistance
VIOUT Rise Time
Propagation Delay Time
Response Time
Internal Bandwidth2
Nonlinearity
Symmetry
VIOUT Saturation Voltages
Quiescent Output Voltage
Power-On Time
VCC
ICC
CLOAD
RLOAD
RIP
tr
tPROP
tRESPONSE
BWI
ELIN
ESYM
VCC = 3.3 V, output open
VIOUT to GND
VIOUT to GND
EX package, TA = 25°C
LC package, TA = 25°C
IP = IPMAX, TA = 25°C, COUT = open
IP = IP(max), TA = 25°C, COUT = open
IP = IP(max), TA = 25°C, COUT = open
–3 dB, TA = 25°C
Over full range of IP
Apply full scale IP
VIOH
VIOL
VIOUT(Q)
tPO
IP = 0 A, TA = 25°C
Output reaches 90% of steady-state level, TA = 25°C,
20 A present on primary conductor
3
3.3
5.5
V
–
4
5.5
mA
–
–
1
nF
15
–
–
kΩ
–
0.6
–
mΩ
–
1.2
–
mΩ
–
3.5
–
μs
–
1.2
–
μs
–
4.6
–
μs
–
100
–
kHz
–
±1
–
%
–
100
–
%
VCC–
0.3
–
–
V
–
–
0.3
V
–
VCC / 2
–
V
–
35
–
μs
¯F¯¯A¯U¯¯L¯¯T¯ Pin Characteristics
¯F¯¯A¯U¯¯L¯¯T¯ Operating Point
¯F¯¯A¯U¯¯L¯¯T¯ Output Pullup
Resistor
IFAULT
RPU
–
± 1 x IP
–
A
1
–
–
kΩ
¯F¯¯A¯U¯¯L¯¯T¯ Output Voltage
¯F¯¯A¯U¯¯L¯¯T¯ Response Time
VCC Off Voltage Level for
Fault Reset3
VOH
VOL
tFAULT
VCCFR
RPU = 1 kΩ
Measured from | IP | > | IFAULT | to VFAULT ≤ VOL
–
VCC–
0.3
–
V
–
0.3
–
V
–
1.3
–
μs
–
–
200
mV
VCC Off Duration for
Fault Reset3
tCCFR
100
–
–
μs
1Devices are programmed for maximum accuracy at 3.3 V VCC levels. The device contains ratiometry circuits that accurately alter the 0 A Output
Voltage and Sensitivity level of the device in proportion to the applied VCC level. However, as a result of minor nonlinearities in the ratiometry circuit
additional output error will result when VCC varies from the 3.3 V VCC level. Customers that plan to operate the device from a 5 V regulated supply
should contact their local Allegro sales representative regarding expected device accuracy levels under these bias conditions.
2Calculated using the formula BWI = 0.35 / tr.
3After the ¯F¯¯A¯U¯¯L¯¯T¯ pin is latched low, the only way to reset it is through a power-off and power-on cycle on the VCC pin. For fault reset, VCC must stay
below VCCFR for a period greater than tCCFR before settling to the normal operation voltage (3 to 5.5 V).
Allegro MicroSystems, LLC
4
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.