ACS712
Fully Integrated, Hall Effect-Based Linear Current Sensor IC
with 2.1 kVRMS Isolation and a Low-Resistance Current Conductor
x05B PERFORMANCE CHARACTERISTICS1 TA = –40°C to 85°C, CF = 1 nF, and VCC = 5 V, unless otherwise specified
Characteristic
Symbol
Test Conditions
Min. Typ.
Max.
Units
Optimized Accuracy Range
IP
–5
–
5
A
Sensitivity
Sens Over full range of IP, TA = 25°C
180
185
190
mV/A
Noise
VNOISE(PP)
Peak-to-peak, TA = 25°C, 185 mV/A programmed Sensitivity,
CF = 47 nF, COUT = open, 2 kHz bandwidth
–
21
–
mV
Zero Current Output Slope
∆IOUT(Q)
TA = –40°C to 25°C
TA = 25°C to 150°C
–
–0.26
–
–
–0.08
–
mV/°C
mV/°C
Sensitivity Slope
∆Sens
TA = –40°C to 25°C
TA = 25°C to 150°C
–
0.054
–
–
–0.008
–
mV/A/°C
mV/A/°C
Total Output Error2
ETOT IP =±5 A, TA = 25°C
–
±1.5
–
%
1Device may be operated at higher primary current levels, IP, and ambient temperatures, TA, provided that the Maximum Junction Temperature, TJ(max),
is not exceeded.
2Percentage of IP, with IP = 5 A. Output filtered.
x20A PERFORMANCE CHARACTERISTICS1 TA = –40°C to 85°C, CF = 1 nF, and VCC = 5 V, unless otherwise specified
Characteristic
Symbol
Test Conditions
Min. Typ.
Max.
Units
Optimized Accuracy Range
IP
–20
–
20
A
Sensitivity
Sens Over full range of IP, TA = 25°C
96
100
104
mV/A
Noise
VNOISE(PP)
Peak-to-peak, TA = 25°C, 100 mV/A programmed Sensitivity,
CF = 47 nF, COUT = open, 2 kHz bandwidth
–
11
–
mV
Zero Current Output Slope
∆IOUT(Q)
TA = –40°C to 25°C
TA = 25°C to 150°C
–
–0.34
–
–
–0.07
–
mV/°C
mV/°C
Sensitivity Slope
∆Sens
TA = –40°C to 25°C
TA = 25°C to 150°C
–
0.017
–
–
–0.004
–
mV/A/°C
mV/A/°C
Total Output Error2
ETOT IP =±20 A, TA = 25°C
–
±1.5
–
%
1Device may be operated at higher primary current levels, IP, and ambient temperatures, TA, provided that the Maximum Junction Temperature,
TJ(max), is not exceeded.
2Percentage of IP, with IP = 20 A. Output filtered.
x30A PERFORMANCE CHARACTERISTICS1 TA = –40°C to 85°C, CF = 1 nF, and VCC = 5 V, unless otherwise specified
Characteristic
Symbol
Test Conditions
Min. Typ.
Max.
Units
Optimized Accuracy Range
IP
–30
–
30
A
Sensitivity
Sens Over full range of IP, TA = 25°C
63
66
69
mV/A
Noise
VNOISE(PP)
Peak-to-peak, TA = 25°C, 66 mV/A programmed Sensitivity,
CF = 47 nF, COUT = open, 2 kHz bandwidth
–
7
–
mV
Zero Current Output Slope
∆IOUT(Q)
TA = –40°C to 25°C
TA = 25°C to 150°C
–
–0.35
–
–
–0.08
–
mV/°C
mV/°C
Sensitivity Slope
∆Sens
TA = –40°C to 25°C
TA = 25°C to 150°C
–
0.007
–
–
–0.002
–
mV/A/°C
mV/A/°C
Total Output Error2
ETOT IP = ±30 A, TA = 25°C
–
±1.5
–
%
1Device may be operated at higher primary current levels, IP, and ambient temperatures, TA, provided that the Maximum Junction Temperature,
TJ(max), is not exceeded.
2Percentage of IP, with IP = 30 A. Output filtered.
Allegro MicroSystems, Inc.