Current Sensor: ACS750xCA-075
Standards and Physical Specifications
Parameter
Flammability (package molding compound)
Safety
Fire and Electric Shock
Creepage distance, current terminals to sensor pins
Clearance distance, current terminals to sensor pins
Package mass
Specification
UL recognized to UL 94V-0
UL recognized to EN 50178
UL60950-1:2003
EN60950-1:2001
CAN/CSA C22.2 No. 60950-1:2003
7.25 mm
7.25 mm
4.18 g typical
Peak to Peak Noise, applying low-pass filter to ACS750 output
Low Pass Filter Break Frequency
Typical Peak to Peak Noise
Unfiltered
22.7 mV
1.4 MHz
21 mV
24 kHz
7.1 mV
Step Response, IPRIMARY = 0 to 50 A
ACS750 Output (mV)
Applied Step (A)
ACS75075-DS Rev. 7
9
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000