5-2. Electronic Characteristics
Operating temperature:
Terminating source impedance:
Terminating load impedance:
TA = -10 … +80 °C
ZS = 50 Ω unbalanced and matching network
ZL = 50 Ω unbalanced and matching network
Characteristics
Minimum Typical Maximum Units
Centre Frequency
Minimum insertion attenuation
(including matching network)
Bandwidth
αrel 3 dB
Amplitude ripple (p-p)
f C±7MHz
Group delay ripple (p-p)
fC±7MHz
Triple transit suppression
Relative attenuation (relative to αmin)
357.5 ~ 352.0 MHz
352.0 ~ 341.0 MHz
341.0 ~ 224.0 MHz
390.5 ~ 392.0 MHz
392.0 ~ 396.0 MHz
396.0 ~ 422.0 MHz
422.0 ~ 454.0 MHz
Temperature coefficient of frequency
fC
α min
BW 3dB
Δα
Δτ
αrel
T Cf
--
374.000
--
MHz
--
9.0
10.5
dB
17
22
--
MHz
--
0.5
1.0
dB
--
40
100
ns
30
40
--
dB
30
42
40
45
48
52
20
38
30
42
38
44
40
45
--
-87
--
dB
--
dB
--
dB
--
dB
--
dB
--
dB
--
dB
--
ppm/K
iCAUTION: Electrostatic Sensitive Device. Observe precautions for handling!
1. The frequency fC is defined as the midpoint between the 3dB frequencies.
2. Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture that is
connected to a 50 Ω test system with VSWR 1.2:1. The test fixture L and C are adjusted for minimum
insertion loss at the filter centre frequency, f C. Note that insertion loss, bandwidth, and passband shape are
dependent on the impedance matching component values and quality.
3. Unless noted otherwise, specifications apply over the entire specified operating temperature range.
4. The specifications of this device are based on the test circuit shown above and subject to change or
obsolescence without notice.
5. All equipment designs utilizing this product must be approved by the appropriate government agency prior to
manufacture or sale.
6. Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications,
processes and circuits implemented within components or assemblies.
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at:
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
Issue : 1 C1
Date : SEPT 04
http://www.actcrystals.com
3 OF 3
Share Link: GO URL

All Rights Reserved © qdatasheet.com  [ Privacy Policy ] [ Contact Us ]