The maximum value of the
shutter is dependent upon the
clock frequency. The formula for
the maximum shutter value is:
Max shutter value = clock freq – 3476
1500
For a clock frequency of 24 MHz,
the following table shows the
maximum shutter value. 1 clock
cycle is 41.67 nsec.
Frames/second
1512
Max Shutter
Decimal
Hex
12397
0x306D
Shutter
Upper
Lower
30
6D
Default Max Shutter
Inverse_Product
Access: Read
Address: 0x11
Reset Value: 0xFF
Bit
7
6
5
4
3
2
1
0
Field Reserved
Reserved
Reserved
Reserved
IP3
IP2
IP1
IP0
Data Type: 4 bit number.
USAGE: Status information and type of mouse sensor
Field name Description
Reserved Reserved for future use
IP3-IP0
Inverse Product ID (x1111b or xFh)
Ordering Information
Specify part number as follows:
ADNS-2610 = 8-pin staggered dual inline package (DIP), 40 per tube.