Table 4. AC Characteristics
Applicable over recommended operating range from TA = –40°C to +125°C, VCC = +2.7V
to +5.5V, CL = 1 TTL Gate and 100 pF (unless otherwise noted)
2.7V, 5.0V
Symbol
Parameter
Min
Max
Units
fSCL
tLOW
tHIGH
tAA
tBUF
Clock Frequency, SCL
1000
kHz
Clock Pulse Width Low
0.4
µs
Clock Pulse Width High
0.4
µs
Clock Low to Data Out Valid
0.05
0.55
µs
Time the bus must be free before a new
transmission can start(1)
0.5
µs
tHD.STA
tSU.STA
tHD.DAT
tSU.DAT
tR
tF
tSU.STO
tDH
tWR
Endurance(1)
Start Hold Time
Start Set-up Time
Data In Hold Time
Data In Set-up Time
Inputs Rise Time(1)
Inputs Fall Time(1)
Stop Set-up Time
Data Out Hold Time
Write Cycle Time
5.0V, 25°C, Page Mode
0.25
µs
0.6
µs
0
µs
100
ns
0.3
µs
100
ns
0.25
µs
50
ns
5
ms
1M
Write
Cycles
Note: 1. This parameter is ensured by characterization only.
4 AT24C11
5093D–SEEPR–2/07