DC Electrical Characteristics
TA = -40°C to 85°C
Symbol Parameter
Test Condition
ILI
Input Leakage Current
VSS < VIN < VCC
ILO
Output Leakage Current
VSS < VOUT < VCC,
SCS1 = VIH or SCS2=VIL or
SOE = VIH or SWE = VIL or
SUB = VIH, SLB = VIH
ICC
Operating Power Supply Current SCS1 = VIL, SCS2=VIH,
VIN = VIH or VIL, II/O = 0 mA
ICC1
Average Operating Current
SCS1 = VIL, SCS2 = VIH,
VIN = VIH or VIL, Cycle Time = Min
100% Duty, II/O = 0 mA
SCS1 < 0.2V, SCS2 > VCC - 0.2V
VIN < 0.2V or VIN > VCC - 0.2V,
Cycle Time = 1 µs
100% Duty, II/O = 0 mA
ISB
Standby Current (TTL Input)
SCS1 = VIH or SCS2 = VIL or
SUB, SLB = VIH
VIN = VIH or VIL
ISB1
Standby Current (CMOS Input) SCS1 > VCC - 0.2V or
SCS2 < VSS + 0.2V or
SUB, SLB > VCC - 0.2V
VIN > VCC - 0.2V or
VIN < VSS + 0.2V
VOL
Output Low
IOL = 0.1 mA
VOH
Output High
IOH = -0.1 mA
Capacitance(1)
(Temp = 25°C, f = 1.0 MHz)
Symbol
Parameter
Condition
CIN
Input Capacitance (Add, SCS1,
SCS2, SLB, SUB, SWE, SOE)
VIN = 0 V
COUT
Output Capacitance (I/O)
VI/O = 0 V
Note: 1. These parameters are sampled and not 100% tested.
Min
-1
-1
SL
LL
2.4
Max
8
10
Max
Unit
1
µA
1
µA
5
mA
35
mA
5
mA
0.5
mA
4
µA
15
µA
0.4
V
V
Unit
pF
pF
32 AT52BR1672(T)/1674(T)
2604B–STKD–09/02