Electrical Characteristics
Absolute Maximum Ratings
Parameter
Min
Typ
Max Unit
Supply Voltage VCC,
VDA, VDDA
Input Voltage, Digital
4.75
-0.3
5.25
V
VDD
+0.3
V
Input Voltage, Analog -0.3
VDA
+0.3
V
Input Voltage, CI and
VI inputs
1.25
3.75
V
Ambient Operating
Temp.
-25
+70
C
Storage Temperature -65
+150
C
Calibration Characteristics
Parameter
Gain Calibration
Calibration Range ±
Calibration
Resolution
Phase Calibration
Calibration Range ±
Calibration
Resolution
Offset Calibration,
Active Power
Calibration Range
Calibration
Resolution
Range,% of Full
Scale Phase Power
Offset Calibration,
Reactive Power
Calibration Range
Calibration
Resolution
Range,% of Full
Scale Phase Power
Min
Typ
Max Units
20
%
0.16
%
5.625
0.044
degree
degree
89.8
W
0.7015
W
0.4157
%
98.7
VAr
0.7712
VAr
0.457
%
Measurement Accuracy
The accuracy measurements are based on the usage of
the AT73C500 DSP with the single-ended ADC,
AT73C501. Using the differential-ended ADC, AT73C502,
improves some of the results.
Input Conditions
When specifying measurement accuracy, it is assumed
that 80ARMS phase current will produce 2VPP full scale input
voltage to current converters. The basic current, IB, is sup-
posed to be 5ARMS.
The nominal phase voltage, UN, is specified to be 230VRMS
and 2VPP full scale input is produced by 270VRMS.
Overall Accuracy, Active and Reactive Power and
Energy Measurement
Overall accuracy including errors caused by A/D-conver-
sion of current and voltage signals, calibration and calcula-
tions.
The accuracy figures are measured in nominal conditions
unless otherwise indicated in the parameter field of the
table below.
Parameter
Nominal voltage, UN
Full-scale voltage, UFS
Full-scale current, IFS
Base current, IB
Frequency, f
Power factor, PF
Harmonic contents of voltage
Harmonic contents of current
Temperature, T
AT73C500 master clock
Nominal Value
230V, ±1%
270V
80A
5A
50.0 Hz, ±0.3%
1
less than 2%
less than 20%
23°C, ±2°C
3.2768 MHz
24
AT73C500