DC and AC Operating Conditions
Operating Temperature (Ambient)
VCCINT or VCCIO (5V) Power Supply
VCCIO (3.3V) Power Supply
Commercial
0°C - 70°C
5V ± 5%
2.7V - 3.6V
Industrial
-40°C - 85°C
5V ± 10%
2.7V - 3.6V
DC Characteristics(1)
Symbol Parameter
Condition
Min
Typ
Max
IIL
Input or I/O Low
Leakage Current
VIN = VCC
-2
-10
IIH
Input or I/O High
Leakage Current
2
10
IOZ
Tri-state Output
Off-state Current
VO = VCC or GND
-40
40
ICC1
Power Supply
VCC = Max
Std Mode Com.
160
Current, Standby
VIN = 0, VCC
Ind.
180
“L” Mode Com.
10
Ind.
10
ICC2
ICC3(2)
Power Supply Current,
Power-down Mode
Reduced-power Mode
Supply Current
VCC = Max
VIN = 0, VCC
VCC = Max
VIN = 0, VCC
“PD” Mode
Std Mode
Com.
Ind.
1
10
65
85
VCCIO
Supply Voltage
5.0V Device Output
Com.
4.75
Ind.
4.5
5.25
5.5
VCCIO
VIL
VIH
VOL
Supply Voltage
Input Low Voltage
Input High Voltage
Output Low Voltage (TTL)
3.3V Device Output
3.0
-0.3
2.0
VIN = VIH or VIL
VCCIO = MIN, IOL = 12 mA
Com.
Ind.
3.6
0.8
VCCIO + 0.3
0.45
0.45
Output Low Voltage (CMOS)
VIN = VIH or VIL
VCC = MIN, IOL = 0.1 mA
Com.
Ind.
0.2
0.2
VOH
Notes:
Output High Voltage (TTL)
VIN = VIH or VIL
VCCIO = MIN, IOH = -4.0 mA
2.4
1. Not more than one output at a time should be shorted. Duration of short circuit test should not exceed 30 sec.
2. ICC3 refers to the current in the reduced-power mode when macrocell reduced-power is turned ON.
Units
µA
µA
µA
mA
mA
µA
µA
mA
mA
mA
V
V
V
V
V
V
V
V
V
V
14 ATF1508AS(L)
0784O–PLD–09/02