ATS616LSG
Dynamic Self-Calibrating Peak-Detecting Differential
Hall Effect Gear Tooth Sensor IC
OPERATING CHARACTERISTICS over operating voltage and temperature range, unless otherwise noted
Characteristic
Symbol Test Condition
Min. Typ.1 Max. Units
ELECTRICAL CHARACTERISTICS
Supply Voltage2
VCC Operating, TJ < 165C
3.5
–
24
V
Power-On State
POS VCC = 0 → 5 V
– HIGH –
V
Undervoltage Lockout Threshold
VCC(UV) VCC = 0 → 5 V; VCC = 5 → 0 V
–
–
3.5
V
Output On Voltage
VOUT(SAT) IOUT = 20 mA
–
200 400 mV
Supply Zener Clamp Voltage
VZsupply ICC = 16 mA, TA = 25°C
28
–
–
V
Output Zener Clamp Voltage
VZoutput IOUT = 3 mA, TA = 25°C
30
–
–
V
Supply Zener Current
IZsupply VS = 28 V
–
–
15
mA
Output Zener Current
IZoutput VOUT = 30 V
–
–
3
mA
Output Current Limit
Output Leakage Current
Supply Current
Power-On Time
Output Rise Time3
Output Fall Time3
PERFORMANCE CHARACTERISTICS
IOUTM VOUT = 12 V
IOUTOFF VOUT = 24 V
ICC
VCC > VCC(min)
tPO VCC > 5 V
tr
RLOAD = 500 Ω, CS = 10 pF
tf
RLOAD = 500 Ω, CS = 10 pF
25
45
55
mA
–
–
15
μA
3
6
12
mA
–
80 500 μs
–
0.3
5.0
μs
–
0.2
5.0
μs
Operating Air Gap Range
Operating Magnetic Flux Density
Differential4
Operating Frequency
AG Operating within specification, Target Speed > 10 rpm
BAG(p-p) Operating within specification, Target Speed > 10 rpm
ƒ
0.4
–
2.5 mm
60
–
–
G
10
– 10 000 Hz
Initial Calibration Cycle5
ncal Output edges before calibration is completed, at fsig < 100 Hz 1
1
1
Calibration Mode Disable
ndis Output falling edges for startup calibration to be complete
64
64
64
Relative Timing Accuracy, Sequential
Allowable User Induced Differential Offset4
Eθ
∆BApp
Target Speed = 1000 rpm, BAG(p-p) > 100 G
Target Speed = 1000 rpm, BAG(p-p) > 60 G
Output switching only; may not meet data sheet specifica-
tions
–
±0.5 ±0.75
–
–
±1.5
–
–
±50
1Typical data is at VCC = 8 V and TA = 25°C. Performance may vary for individual units, within the specified maximum and minimum limits.
2 Maximum voltage must be adjusted for power dissipation and junction temperature; see Power Derating section.
3 CS is the probe capacitance of the oscilloscope used to make the measurement.
4 10 G = 1 mT (millitesla), exactly.
5Non-uniform magnetic profiles may require additional edges before calibration is complete.
Edge
Edge
G
Allegro MicroSystems, Inc.
3
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com