CORPORATION
CL432
ELECTRICAL CHARACTERISTICS
Electrical characteristics are guaranteed over full junction temperature range (0 to 105oC). Ambient temperature must be derated based on
power dissipation and package thermal characteristics. The conditions are: VKA = VREF and IK = 10mA unless otherwise stated.
SYMBOL
PARAMETER
MIN
TYP
MAX UNIT
TEST CONDITION
VREF
Output Voltage
1.244
1.250
1.256
V
IK = 10mA, TJ = 25oC, VK = VREF
VREF
Line Regulation
10
15
mV VK = 1.25 to 15V
VREF
VREF
Load Regulation
Temperature Deviation
3
6
mV IK = 1 to 100mA
2
6
mV 0 < TJ < 105oC
IREF
Reference Input Current
3
6
µA
I REF
Reference Input Current Temperature
Coefficient
0.3
0.6
µA 0 < TJ < 105oC
IK(MIN)
Min. Cathode Current for Regulation
0.6
1
mA
IK(MIN)
Off State Leakage
0.04
500
nA VREF = 0V, VKA = 18V
*Temperature deviation is defined as the maximum deviation of the reference over the given temperature range and does not imply an
incremental deviation at any given temperature.
TYPICAL PERFORMANCE CURVES (Not available at time of publishing)
Calogic reserves the right to make changes without further notice to any products described herein to improve reliability, function,
or design. Calogic does not assume any liability arising out of the application or use of any product or circuit described herein;
neither does it convey any license under its patent rights or the right of others. Calogic products are not authorized for use as
components in life support devices or systems intended for surgical implant into the body or intended to support or sustain life.
Buyer agrees to notify Calogic of any such intended end use whereupon Calogic will determine availability and suitability of its
products for the intended use. Calogic and the Calogic logo are trademarks of Calogic.
CALOGIC CORPORATION, 237 Whitney Place, Fremont, California 94539, Telephone: 510-656-2900, FAX: 510-651-3025