Frequency Domain Split Band Scrambler
CMX264
10
0
-10
-20
-30
-40
-50
100
1000
Frequency (Hz)
Figure 6a
10000
100000
4
3
2
1
0
-1
-2
-3
-4
-5
-6
100
1000
Frequency (Hz)
Figure 6b
10000
Figure 6: Typical Response Envelope of Scramble Signal at MICO pin, relative to MICIN,
with Split Point 4 Selected.
© 1999 Consumer Microcircuits Limited
21
D/CMX264/1