Digital Line to POTS Interface
Page 25 of 26
CMX605 Preliminary Information
6.1.4 Timing
tCSE
tCSH
tLOZ
tHIZ
tCSOFF
tNXT
tCK
tCH
tCL
tCDS
tCDH
tRDS
tRDH
‘C-BUS’ Timings (See Figure 13)
CS -Enable to Clock-High time
Last Clock-High to CS -High time
Clock-Low to Reply Output enable time
CS -High to Reply Output 3-state time
CS -High Time between transactions
Inter-Byte Time
Clock-Cycle time
Serial Clock-High time
Serial Clock-Low time
Command Data Set-Up time
Command Data Hold time
Reply Data Set-Up time
Reply Data Hold time
Notes Min. Typ. Max. Unit
100
-
-
ns
100
-
-
ns
0.0
-
-
ns
-
-
1.0 µs
1.0
-
-
µs
500
-
500
-
200
-
200
-
75
-
25
-
75
-
0
-
-
ns
-
ns
-
ns
-
ns
-
ns
-
ns
-
ns
-
ns
Table 21: C-BUS Timing
Note: These timings are for the latest version of the ‘C-BUS’ as embodied in the CMX605, and allow faster
transfers than the original ‘C-BUS’ timings provided in MX-COM’s Publication Doc. # 20480060.001.
CS
tCSE
SERIAL CLOCK
tCK
tNXT
tCSH
tCSOFF
COMMAND DATA
REPLY DATA
765432 10
tLOZ
HI-Z
= Level not important or undefined
765432 10
tHIZ
765432 10
70% VDD
30% VDD
COMMAND
DATA
tCL
tCDS
tCH
tCDH
SERIAL
CLOCK
REPLY
DATA
tCK
tRDS
Figure 13: ‘C-BUS’ Timing
tRDH
¤2001 MX-COM, Inc.
www.mxcom.com tel: 800 638 5577 336 744 5050 fax: 336 744 5054
Doc. # 20480195.005
4800 Bethania Station Road, Winston-Salem, NC 27105-1201 USA All trademarks and service marks are held by their respective companies.