CPC7583
1.7 Additional Electrical Characteristics
Parameter
Test Conditions
Symbol Minimum Typical Maximum
Unit
Digital Inputs
Input low voltage
Input high voltage
-
VIL
-
-
1.5
V
-
VIH
3.5
-
-
Input leakage current
(high)
VDD = 5.5 V, VBAT = -75 V, VIH = 5 V
IIH
-
0.1
1
μA
Input leakage current
(low)
VDD = 5.5 V, VBAT = -75 V, VIL = 0 V
IIL
-
0.1
1
Voltage Requirements
VDD
-
VDD
4.5
5.0
5.5
V
VBAT1
-
VBAT
-19
-
-72
V
1VBAT is used only for internal protection circuitry. If VBAT goes more positive than -10 V, the device will enter the all-off state and will remain in the all-off state until
the battery goes more negative than -15 V
Power Requirements
Power consumption in VDD = 5 V, VBAT = -48 V, measure IDD
talk and all-off states and IBAT
P
Power consumption in VDD = 5 V, VBAT = -48 V, measure IDD
any other state
and IBAT
P
-
3.5
7.5
mW
5.0
10.5
VDD current in talk and
all-off states
VDD current in any other
VDD = 5 V, VBAT = -48 V
state
IDD
-
0.7
1.5
mA
IDD
-
1.0
1.9
VBAT current in any state VDD = 5V, VBAT = -48 V
IBAT
-
4
10
μA
Temperature Shutdown Requirements (temperature shutdown flag is active low)
Shutdown activation
temperature
Not production tested - limits are
TSD_on
110
125
150
°C
guaranteed by design and Quality
Shutdown circuit
hysteresis
Control sampling audits.
TSD_off
10
-
25
°C
R06
www.clare.com