CS43L43
5.1.3 POPGUARD® TRANSIENT CONTROL (POR) BIT 4
Default - 1
0 - Disabled
1 - Enabled
Function:
The Popguard® Transient Control allows the quiescent voltage to slowly ramp to and from 0 volts to the
quiescent voltage during power-on or power-off when this feature is enabled. Please see section 3.6 for
implementation details.
5.1.4 POWER DOWN (PDN) BIT 1
Default = 1
0 - Disabled
1 - Enabled
Function:
The entire device will enter a low-power state whenever this function is enabled, but the contents of the
control registers will be retained in this mode. The power-down bit defaults to ‘enabled’ on power-up and
must be disabled before normal operation will begin.
5.1.5 CONTROL PORT ENABLE (CP_EN) BIT 0
Default = 0
0 - Disabled
1 - Enabled
Function:
The Control Port will become active and reset to the default settings when this function is enabled.
16
DS479PP3