CY7C1019BV33
CY7C1018BV33
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature ................................. –65°C to +150°C
Ambient Temperature with
Power Applied ............................................. –55°C to +125°C
Supply Voltage on VCC to Relative GND[1] .... –0.5V to +7.0V
DC Voltage Applied to Outputs
in High Z State[1] ....................................–0.5V to VCC + 0.5V
DC Input Voltage[1].................................–0.5V to VCC + 0.5V
Electrical Characteristics Over the Operating Range
Current into Outputs (LOW)......................................... 20 mA
Static Discharge Voltage ........................................... >2001V
(per MIL-STD-883, Method 3015)
Latch-Up Current..................................................... >200 mA
Operating Range
Range
Commercial
Ambient
Temperature[2]
0°C to +70°C
VCC
3.3V ± 10%
Parameter
Description
VOH
Output HIGH Voltage
VOL
Output LOW Voltage
VIH
Input HIGH Voltage
Test Conditions
VCC = Min.,
IOH = – 4.0 mA
VCC = Min.,
IOL = 8.0 mA
VIL
Input LOW Voltage[1]
IIX
Input Load Current GND < VI < VCC
IOZ
Output Leakage
GND < VI < VCC,
Current
Output Disabled
ICC
VCC Operating
VCC = Max.,
Supply Current
IOUT = 0 mA,
f = fMAX = 1/tRC
ISB1
Automatic CE
Max. VCC, CE > VIH
Power-Down Current VIN > VIH or
—TTL Inputs
VIN < VIL, f = fMAX
ISB2
Automatic CE
Max. VCC,
Power-Down Current CE > VCC – 0.3V,
—CMOS Inputs
VIN > VCC – 0.3V,
L
or VIN < 0.3V, f = 0
7C1019BV33-10 7C1019BV33-12 7C1019BV33-15
7C1018BV33-10 7C1018BV33-12 7C1018BV33-15
Min. Max. Min. Max. Min. Max. Unit
2.4
2.4
2.4
V
0.4
0.4
0.4
V
2.2
VCC
2.2
VCC
2.2
VCC
V
+ 0.3
+ 0.3
+ 0.3
–0.3
0.8
–0.3
0.8
–0.3
0.8
V
–1
+1
–1
+1
–1
+1 µA
–5
+5
–5
+5
–5
+5 µA
175
160
145 mA
20
20
20 mA
5
5
5
mA
−
0.5
0.5
Capacitance[3]
Parameter
Description
Test Conditions
CIN
COUT
Input Capacitance
Output Capacitance
TA = 25°C, f = 1 MHz,
VCC = 5.0V
Notes:
1. VIL (min.) = –2.0V for pulse durations of less than 20 ns.
2. TA is the “Instant On” case temperature.
3. Tested initially and after any design or process changes that may affect these parameters.
Max.
Unit
6
pF
8
pF
2