2.7.Lighting Specifications
2.7.1.Absolute Maximum Ratings
Ta=25℃
Parameter
Symbol
Conditions
Min. Typ. Max. Units
Reverse Voltage
VR
Note 1
-
-
9.0
V
LED Power Dissipation
PD
-
-
-
1.5
mW
Note 1 : VF is defined as the voltage between ANODE and CATHODE as shown below.
ANODE
R
VF
CATHODE
2.7.2.Operating Characteristics
Parameter
Foward Current
Luminance of
Backlight Surface
Symbol
IF
L
Conditions
VF=5.0V
VF=5.0V
Ta=25℃
Min. Typ. Max. Units
117
176
235
mA
60
-
-
cd/㎡
DMF-51026NYU-LY (AA) No.2000-0179
OPTREX CORPORATION
OPTREX