3.3. Definition of Viewing Angle and Optimum Viewing Area
*Point • shows the point where contrast ratio is measured. : θ= 0°, φ= -°
*Driving condition : 1/128 Duty, 1/12.3 Bias, VD=18.8V, fF=70Hz
90°
135°
45°
180°
225°
φ
10 20 30 40 50
θ
(φ = 0°)
180°
270°
315°
θ
270°
90°
φ
0°
*Area
shows typ. CR≥2
3.4.System Block Diagram
Photometer
#1980A WB
Temperature Chamber
Rotation Table ( θ,φ )
φ
LCD
Optical Fiber
θ
Computer
Control Unit &
Waveform Generator
Halogen bulb
DMF5001NYL-ACE-AX (AX) No. 2001-0241
OPTREX CORPORATION
Page 7/16