Qdatasheet_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

DMS-20PC-0/5-5RH-C View Datasheet(PDF) - Murata Power Solutions

Part Name
Description
MFG CO.
'DMS-20PC-0/5-5RH-C' PDF : 4 Pages View PDF
1 2 3 4
Performance/Functional Specifications
Typical at TA = +25°C, unless otherwise noted.
Inputs
Min. Typ. Max. Units
Full Scale Input Range~
4.9
5.0
5.1 Volts
Input Impedence
100
–
140 kΩ
Overvoltage Protection 
–
–
±40 Volts
Performance
Sampling Rate
2.5 reading per second
Accuracy (1 minute warm-up):
±0.05%FS ±1 Count
Temperature Drift (0 to +60°C)
– ±0.15 ±0.3 Cnts/°C
Power Supply Requirements
DMS-20PC-0/5-5RS (@90mA max.) +4.75 +5.00 +5.25 Volts
DMS-20PC-0/5-5GS (@120mA max.) +4.75 +5.00 +5.25 Volts
DMS-20PC-0/5-5RL (@15mA max.) +4.75 +5.00 +5.25 Volts
DMS-20PC-0/5-5RH (@90mA max.) +4.75 +5.00 +5.25 Volts
DMS-20PC-0/5-24RS (@15mA max.) +4.75
– +40.0 Volts
Display
Display Type and Size
3½ digit, 0.37"/9.4mm high LED
Polarity Indication
"–" for negative VIN
Overrange Indication
"–1_ _ _ " for negative inputs
"1_ _ _ " for positive inputs
Physical/Environmental
Operating Temperature
0
–
+60
°C
Storage Temperature
–20
–
+75
°C
Humidity (non-condensing)
0
–
95
%
Case Material
Polycarbonate
Weight
0.6 ounces (17 grams)
~ The DMS-20PC-0/5 can also be used in most 0-10V applications. See the section
on 0-10V inputs for more information. See Note 3 on Table 1.
 INPUT LO (TB1 "–LO") is internally connected to the power return (TB2 "–V").
Overvoltage specifications apply to the INPUT HI (TB1 "+HI") connection.
Ordering Information
DMS-20PC-0/5-5RS-C +5V supply, standard-intensity red LED's
DMS-20PC-0/5-5GS-C +5V supply, standard-intensity green LED's
DMS-20PC-0/5-5BS-C +5V supply, bright blue LED's
DMS-20PC-0/5-5RL-C +5V supply, low-power red LED's
DMS-20PC-0/5-5RH-C +5V supply, high-intensity red LED's
DMS-20PC-0/5-24RL-C +5V to +40V supply, low-power red LED's
DMS-PS1-CM-C
+5V/1.0A AC/DC power supply module
DMS-PS4-CM-C
+24V/0.45A AC/DC power supply module
DMS-PS7-CM-C
+24V/0.7A AC/DC power supply module
DMS-20-CP
Panel cutout punch
Note: A DMS-BZL4 bezel assembly with a sealing gasket is supplied with each meter.
DMS-20PC-0/5 Series
0-5V and 0-10V Input 3½ Digit, LED
Display Process Control Monitors
TECHNICAL NOTES
1. Input Configuration: The DMS-20PC-0/5 has its input low terminal
(TB1 "LO") internally connected to the power supply ground terminal
(TB2 "–V"). This connection effectively places the meter's input in a
single-ended configuration. In some applications, single-ended inputs
can cause ground-loop induced errors (the meter's display becomes
unstable or bounces). This occurs because the LED drive currents
flow through both the –V terminal and the signal LO terminal.
If suspected ground-loop errors are encountered, and the input signal
LO terminal is externally connected to –V somewhere else in the
system, try removing the connection to TB1 "LO". Inputs which have
no ground-return connection to –V (commonly referred to as "floating
inputs") must have their most negative potential tied to TB1 "LO".
Please consult DATEL for more information.
Applications which require electrical isolation between the input
signal source and the system power supply must use a separate
transformer-isolated supply to power the meter.
2. Panel Mounting: In most standard through-the-panel installations,
the DMS-20PC-0/5 must be secured to the panel with DMS-BZL4
bezel assemblies (see the Mechanical Specifications section for more
information).
OPERATING AND SETUP INSTRUCTIONS
As shipped, the DMS-20PC-0/5 is factory calibrated to read "000" for
a 0.0V input and "1999" for a 5.0V input. The following worst-case
procedure assumes the DMS-20PC-0/5 is completely mis-adjusted, i.e.,
both potentiometers and the DIP switches are randomly set.
1. Set R7 (full scale span/gain adjust) and R3 (zero/offset adjust) fully
clockwise, roughly 22 turns, and place SW1-SW8 to OFF (down
position).
2. Select DIP switch setting #1 in Table 1.
3. Apply a precision 0.0V input and adjust R3 until the meter's display
reads "000".
4. Apply a precision 5.0V input and adjust R7 until the meter's display
reads "1999". Repeat steps 3 and 4 to make sure the adjustments
do not affect one another.
5. Select the appropriate decimal point by setting SW6, SW7 or SW8 to
ON (DP1, DP2 or DP3 respectively).
NOTE: The "000" to "1999" display readings referred to in the
instructions above are for illustrative purposes only. If other display
readings such as "000" to "1200" are desired, refer to the DIP-
Switch Settings Tables for SW1-SW4 settings. (SW5 is reserved for
future use, it has no affect on display operation.) The initial setting
of R3 and R7 fully clockwise is recommended in the adjustment
procedure for all the following examples.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MPM_DMS20pc_5V.B04 Page 2 of 4
Share Link: GO URL

All Rights Reserved Ā© qdatasheet.com  [ Privacy Policy ] [ Contact Us ]