Qdatasheet_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

DMS-20PC-0/5 View Datasheet(PDF) - DATEL Data Acquisition products

Part Name
Description
MFG CO.
DMS-20PC-0/5
Datel
DATEL Data Acquisition products  Datel
'DMS-20PC-0/5' PDF : 4 Pages View PDF
1 2 3 4
D0M- 5SV-20I PNCP -U0T/5, 3 ½ D I G I T , L E D D I S P L A Y P R O C E S S C O N T R O L M O N I T O R S
DMS-20PC-0/5
Applications
Examples (0-5V Inputs)
1. Desired display readings are:
ON
0.0V input = "0.00"
5.0V input = "6.00"
12345678
Use DIP-switch setting #3 in Table 1 and enable decimal point
DP2 via SW7. Apply 0.0V and adjust R3 so the display reads
"0.00". Apply 5.0V and adjust R7 so the display reads "6.00".
2. Desired display readings are:
ON
0.0V input = "000"
5.0V input = "800"
12345678
Use DIP-switch setting #2 in Table 1. Apply 0.0V and adjust R3 so
the display reads "000". Apply 5.0V and adjust R7 so the display
reads "800". For these display readings, no decimal points are
used. Set SW6, SW7 and SW8 to OFF.
3. Desired display readings are:
ON
0.0V input = ".000"
5.0V input = ".250"
12345678
Use DIP-switch setting #5 in Table 1 and enable decimal point
DP1 via SW6. Apply 0.0V and adjust R3 so the display reads
"000". Apply 5.0V and adjust R7 so the display reads ".250".
Table 1. 0-5V DIP-Switch Settings âž‚
Display Reading
SW1 SW2 SW3 SW4
0.0V Input
1. 000
2. 000
3. 000
4. 000
5. 000
6. 000
7. 000
8. 000
5.0V Input
1200-1999
700-1200
400-700
300-400
190-300
120-190
100-150
90-140
Off
Off Off Off
On
Off Off Off
Off
On Off Off
Off
Off On Off
Off
On On Off
Off
Off On On
Off
On On On
On
On On On
âž‚ The DMS-20PC-0/5 is optimized for handling 5V signal ranges that are
positioned between –0.1V and +6.0V. As such, input ranges can be
anywhere between –0.1V to +4.9V and +1.0V to +6.0V as long as their
full range is 5 Volts. The meter's zero/offset potentiometer (R3) has
enough adjustment range to produce a "000" display reading for input
signal levels between – 0.1V and +1.0V.
Please note the DMS-20PC digital panel meter from which the DMS-
20PC-0/5 is derived has an accuracy specification of ±2 counts (max.).
Thus, it may not always be possible to obtain the exact desired display
readings.
4. Desired display readings are:
ON
1.0V input = "000"
6.0V input = "090"
12345678
Even though this input is positioned between +1.0V and +6.0V, it
still meets the 5V full scale input range listed in the Functional
Specifications section. Use DIP-switch setting #8 in Table 1. Apply
1.0V and adjust R3 so the display reads "000". Apply 6.0V and
adjust R7 so the display reads "090". With this type of input, it is
advisable to recheck both input levels to be sure the
potentiometer settings do not affect one another.
0-10V Inputs
While the DMS-20PC-0/5 is optimized for operation with 0-5V inputs,
its versatile input stage can also accommodate most 0-10V
applications. The meter's zero/offset potentiometer (R3) has enough
adjustment range to produce a "000" display reading with input signal
levels between –0.1V and +1.0V. Table 2. summarizes the available
ranges when the DMS-20PC-0/5 is used with 0-10V inputs.
Example (0-10V Inputs)
1. Desired display readings are:
ON
0.0V input = "000"
10.0V input = "500"
12345678
Use DIP switch setting #4 in Table 2. Apply 0.0V and adjust R3 so
the display reads "000". Apply 10.0V and adjust R7 so the display
reads "500".
Table 2. 0-10V DIP-Switch Settings
Display Reading
SW1 SW2 SW3 SW4
0.0V Input 10.0V Input
1. 000
1400-1999
2. 000
800-1400
3. 000
600-800
4. 000
380-600
5. 000
240-380
6. 000
200-300
7. 000
180-280
On Off Off Off
Off On Off Off
Off Off On Off
Off On On Off
Off Off On On
Off On On On
On On On On
3
Share Link: GO URL