CX86500 SCXV.xx Modem Data Sheet
2.3.7
Connection Speeds
The modem functions as a data modem when the +FCLASS=0 command is active.
Line connection can be selected using the +MS command. The +MS command selects
modulation, enables/disables automode, and selects minimum and maximum line speeds
(Table 2-1).
Table 2-1. +MS Command Automode Connectivity
Modulation
Bell 103
Bell 212
V.21
V.22
V.22 bis
V.23
V.32
V.32 bis
V.34
V.90
V.92 downstream
V.92 upstream
<carrier>
B103
B212
V21
V22
V22B
V23C
V32
V32B
V34
V90
V92
V92
Possible (<min_rx_rate>, <min_rx_rate>, (<min_tx_rate>),
and <max_tx_rate>) Rates (bps)
300
1200 Rx/75 Tx or 75 Rx/1200 Tx
300
1200
2400 or 1200
1200
9600 or 4800
14400, 12000, 9600, 7200, or 4800
33600, 31200, 28800, 26400, 24000, 21600, 19200, 16800,
14400, 12000, 9600, 7200, 4800, or 2400
56000, 54667, 53333, 52000, 50667, 49333, 48000, 46667,
45333, 44000, 42667, 41333, 40000, 38667, 37333, 36000,
34667, 33333, 32000, 30667, 29333, 28000
56000, 54667, 53333, 52000, 50667, 49333, 48000, 46667,
45333, 44000, 42667, 41333, 40000, 38667, 37333, 36000,
34667, 33333, 32000, 30667, 29333, 28000
48000, 46667, 45333, 44000, 42667, 41333, 40000, 38667,
37333, 36000, 34667, 33333, 32000, 30667, 29333, 28000,
26667, 25333, 24000
2.3.8
2.4
2.4.1
2.4.2
102287F
Automode
Automode detection can be enabled by the +MS command to allow the modem to
connect to a remote modem in accordance with draft PN-3320 for V.34 (Table 2-1).
Data Mode
Data mode exists when a telephone line connection has been established between
modems and all handshaking has been completed.
Speed Buffering (Normal Mode)
Speed buffering allows a DTE to send data to, and receive data from, a modem at a speed
different than the line speed. The modem supports speed buffering at all line speeds.
Flow Control
DTE-to-Modem Flow Control. If the modem-to-line speed is less than the DTE-to-
modem speed, the modem supports XOFF/XON or RTS/CTS flow control with the DTE
to ensure data integrity.
Conexant