CX86500 SCXV.xx Modem Data Sheet
Escape Sequence Detection
The +++ escape sequence can be used to return control to the command mode from the
data mode. Escape sequence detection is disabled by an S2 Register value greater than
127.
BREAK Detection
The modem can detect a BREAK signal from either the DTE or the remote modem. The
\Kn command determines the modem response to a received BREAK signal.
Telephone Line Monitoring
GSTN Cleardown (V.92, V.90, V.34, V.32 bis, V.32). Upon receiving GSTN
Cleardown from the remote modem in a non-error correcting mode, the modem cleanly
terminates the call.
Loss of Carrier (V.22 bis and Below). If carrier is lost for a time greater than specified
by the S10 register, the modem disconnects.
Fall Forward/Fallback (V.92/V.90/V.34/V.32 bis/V.32)
During initial handshake, the modem will fallback to the optimal line connection within
V.92/V.90/V.34/V.32 bis/V.32 mode depending upon signal quality if automode is
enabled by the +MS or N1 command.
When connected in V.92/V.90/V.34/V.32 bis/V.32 mode, the modem will fall forward or
fallback to the optimal line speed within the current modulation depending upon signal
quality if fall forward/fallback is enabled by the %E2 command.
Retrain
The modem may lose synchronization with the received line signal under poor or
changing line conditions. If this occurs, retraining may be initiated to attempt recovery
depending on the type of connection.
The modem initiates a retrain if line quality becomes unacceptable if enabled by the %E
command. The modem continues to retrain until an acceptable connection is achieved, or
until 30 seconds elapse resulting in line disconnect.
Programmable Inactivity Timer
The modem disconnects from the line if data is not sent or received for a specified length
of time. In normal or error-correction mode, this inactivity timer is reset when data is
received from either the DTE or from the line. This timer can be set to a value between 0
and 255 seconds by using register S30. A value of 0 disables the inactivity timer.
DTE Signal Monitoring (Serial DTE Interface Only)
DTR#. When DTR# is asserted, the modem responds in accordance with the &Dn and
&Qn commands.
RTS#. RTS# is used for flow control if enabled by the &K command in normal or error-
correction mode.