CX86500 SCXV.xx Modem Data Sheet
Table 3-2. CX86500 Modem 28-Pin TSSOP with Serial Interface Hardware Signal Definitions (Continued)
Label
TXD#
RXD#
Pin
5
4
CTS#
11
RLSD#
17
RI#
18
DTR#
12
RTS#
10
RXCLK#
6
TXCLK#
8
RESERVED
19
RESERVED
13, 14, 16
Note:
I/O Types: See Table 3-7.
I/O I/O Type
Signal Name/Description
V.24 (EIA/TIA-232-E) DTE Serial Interface
I
Ipu/O2
Transmitted Data (EIA BA/ITU-T CT103). The DTE uses the TXD# line
to send data to the modem for transmission over the telephone line or to
transmit commands to the modem.
O
Ipu/O2
Received Data (EIA BB/ITU-T CT104). The modem uses the RXD# line
to send data received from the telephone line to the DTE and to send
modem responses to the DTE. During command mode, RXD# data
represents the modem responses to the DTE.
O
Ipu/O2
Clear To Send (EIA CB/ITU-T CT106). CTS# output ON (low) indicates
that the modem is ready to accept data from the DTE. In error correction
or normal mode, CTS# is always ON (low) unless RTS/CTS flow control
is selected by the &Kn command.
O
Ipu/O2
Received Line Signal Detector (EIA CF/ITU-T CT109). During normal
operation, when AT&C0 command is not in effect, RLSD#/CLKSEL#
output is ON when a carrier is detected on the telephone line or OFF
when carrier is not detected.
O
Ipu/O2
Ring Indicator (EIA CE/ITU-T CT125). RI# output ON (low) indicates
the presence of an ON segment of a ring signal on the telephone line.
I
Ipu/O2
Data Terminal Ready (EIA CD/ITU-T CT108). The DTR# input is turned
ON (low) by the DTE when the DTE is ready to transmit or receive data.
DTR# ON prepares the modem to be connected to the telephone line,
and maintains the connection established by the DTE (manual
answering) or internally (automatic answering). DTR# OFF places the
modem in the disconnect state under control of the &Dn and &Qn
commands.
I
Ipu/O2
Request To Send (EIA CA/ITU-T CT105). RTS# input ON (low)
indicates that the DTE is ready to send data to the modem. In the
command state, the modem ignores RTS#.
The modem ignores RTS# unless RTS/CTS flow control is selected by
the &Kn command.
O
Ipu/O2
Receive Data Clock. RXCLK# is output in synchronous mode. The
RXCLK# frequency is the data rate (±0.01%) with a duty cycle of 50±1%.
Leave open if not used.
O
Ipu/O2
Transmit Data Clock. TXCLK# is output in synchronous mode. The
TXCLK frequency is the data rate (±0.01%) with a duty cycle of 50±1%.
Leave open if not used.
RESERVED
Reserved. Connect to digital ground (GND).
Reserved. Leave open or connect to digital ground (GND).
102287F
Conexant
3-5