Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Performance characteristics
DSOX2000 Series
(digital signal oscilloscope)
MSOX2000 Series
(mixed signal oscilloscope)
Characteristic 2002A 2004A 2012A 2014A 2022A 2024A 2002A 2004A 2012A 2014A 2022A 2024A
Bandwidth* (-3dB)
70 MHz
100 MHz
200 MHz
70 MHz
100 MHz
200 MHz
Bandwidth
upgrade
YES
YES
NO
YES
YES
NO
Channels
2
4
2
4
2
4
2
4
2
4
2
4
Sample rate on
each channel
1 GSa/s per channel, 2 GSa/s interleaved
Memory depth
(record length)
100 kpts
Display
8.5-inch WVGA with 64 levels of intensity grading
Waveform update
rate
50,000 waveforms/s
External trigger
input
Included on all models
Vertical resolution
8 bits
Vertical sensitivity
(range)
2 mV/div to 5 V/div**
DC vertical
accuracy
±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale]**
DC gain accuracy*
±3% (≥ 10 mV/div); ±4% (< 10 mV/div)**
DC vertical offset
accuracy
±0.1div ±2 mV ±1% of offset setting
Vertical zoom
Ability to scale and position a live or stopped waveform vertically. When the acquisition is stopped, turning the
vertical scale and offset (position) knobs will scale and move the signal. Pan and zoom redraws the waveform in
< 100 ms.
Maximum input
voltage
CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpkCAT II 300 Vrms, 400 Vpk with 10073C 10:1 probe: CAT I
500 Vpk, CAT II 400 Vpk with N2862A or N2863A 10:1 probe: 300 Vrms
Position
range/offset
2 mV to 200 mV/div: ±2 V
>200 mV to 5 V/div: ± 50V
Bandwidth limit
20 MHz selectable
Input coupling
AC, DC, GND
Input impedance
1 MΩ ±2%
Time base range
5 ns/div to
50 s/div
5 ns/div to
50 s/div
2 ns/div to
50 s/div
5 ns/div to
50 s/div
5 ns/div to
50 s/div
2 ns/div to
50 s/div
Time base
accuracy*
25 ppm ±5 ppm per year (aging)
∆ Time accuracy
(using cursors)
± (timebase acc. x reading) ± (0.0016 x screen width) ± 100 ps
Dynamic range
(±8 divisions from center screen)
Horizontal zoom
(modes)
Horizontally expand or compress a live or stopped waveform
Horizontal
resolution
2.5 ps
* Denotes warranted specifications, all others are typical.
Specifications are valid after a 30-minute warm-up period and from ±10 °C firmware calibration temperature.
** 2 mV/div is a magnification of 4 mV/div setting. For vertical accuracy calculations, use full scale of 32 mV for 2 mV/div sensitivity setting.