EVERLIGHT ELECTRONICS CO.,LTD.
Precautions For Use
EHP-B03LS/UT04-P05/TR
1. Over-current-proof
Though EHP-B03 has conducted ESD protection mechanism, customer must not use the device in
reverse and should apply resistors for extra protection. Otherwise slight voltage shift may cause
enormous current change and burn out failure would happen.
2. Storage
i. Do not open moisture proof bag before the products are ready to use.
ii. Before opening the package, the LEDs should be kept at 30℃ or less and 90%RH or less.
iii. The LEDs should be used within a year.
iv. After opening the package, the LEDs should be kept at 30℃ or less and 70%RH or less.
v. The LEDs should be used within 168 hours (7 days) after opening the package.
vi. If the moisture absorbent material (silicone gel) has faded away or the LEDs have exceeded the
storage time, baking treatment should be performed using the following conditions.
vii. Pre-curing treatment : 60±5℃ for 24 hours.
3. Thermal Management
i. For maintaining the high flux output and achieving reliability, EHP-A08 series LED package should
be mounted on a metal core printed circuit board (MCPCB) with proper thermal connection to
dissipate approximately 1W of thermal energy under 350mA operation.
ii. Special thermal designs are also recommended to take in outer heat sink design, such as FR4
PCB on Aluminum with thermal vias or FPC on Aluminum with thermal conductive adhesive, etc.
iii. Sufficient thermal management must be conducted, or the die junction temperature will be over
the limit under large electronic driving and LED lifetime will decrease critically.
Everlight Electronics Co., Ltd.
Device No. :
http://www.everlight.com
Prepared date: 08-20-2007
Rev.1.0
Page: 9 of 10
Prepared by: Brady Chou