AD5122/AD5142
Data Sheet
Table 10. Reduced Commands Operation Truth Table
Control
Command Bits[DB15:DB12]
Number C3 C2 C1 C0
Address
Bits[DB11:DB8]1
A3 A2 A1 A0
Data Bits[DB7:DB0]1
D7 D6 D5 D4 D3 D2 D1 D0
Operation
0
0 0 0 0 X X X X X X X X X X X X NOP: do nothing.
1
0 0 0 1 0 0 0 A0 D7 D6 D5 D4 D3 D2 D1 D0 Write contents of serial register
data to RDAC
2
0 0 1 0 0 0 0 A0 D7 D6 D5 D4 D3 D2 D1 D0 Write contents of serial register
data to input register
3
0 0 1 1 X 0 A1 A0 X X X X X X D1 D0 Read back contents
D1 D0 Data
0
1
EEPROM
1
1
RDAC
9
0 1 1 1 0 0 0 A0 X X X X X X X 1 Copy RDAC register to EEPROM
10
0 1 1 1 0 0 0 A0 X X X X X X X 0 Copy EEPROM into RDAC
14
1 0 1 1 X X X X X X X X X X X X Software reset
15
1 1 0 0 A3 0 0 A0 X X X X X X X D0 Software shutdown
D0 Condition
0
Normal mode
1
Shutdown mode
1X means don’t care.
Table 11. Reduced Address Bits Table
A3
A2
A1
A0
Channel
1
X1
X1
X1
All channels
0
0
0
0
RDAC1
0
0
0
1
RDAC2
0
0
1
0
Not applicable
Stored Channel Memory
Not applicable
RDAC1
Not applicable
RDAC2
1X means don’t care.
Rev. C | Page 22 of 32