ADG936/ADG936-R
ABSOLUTE MAXIMUM RATINGS
TA = 25°C, unless otherwise noted.
Table 2.
Parameter
VDD to GND
Inputs to GND
Continuous Current
Input Power
Operating Temperature Range
Industrial (B Version)
Storage Temperature Range
Junction Temperature
TSSOP Package
θJA Thermal Impedance
LFCSP Package
θJA Thermal Impedance (4-Layer Board)
Lead Temperature, Soldering (10 sec)
IR Reflow, Peak Temperature (<20 sec)
ESD
Rating
–0.5 V to +4 V
–0.5 V to VDD + 0.3 V1
30 mA
18 dBm
–40°C to +85°C
–65°C to +150°C
150°C
143°C/W
30.4°C/W
300°C
235°C
1 kV
Data Sheet
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Only one absolute maximum rating may be applied at any one
time.
Table 3. Truth Table
INx
RF1x
0
Off
1
On
RF2x
On
Off
1 RF1x/RF2x off port inputs to ground = –0.5 V to VDD – 0.5 V.
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on
the human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.
Rev. B | Page 4 of 16