Data Sheet
TYPICAL PERFORMANCE CHARACTERISTICS
–0.3
–0.4
–0.5
–0.6
–0.7
–0.8
–0.9
–1.0
–1.1
VDD = 2.75V
–1.2
–1.3
–1.4
–1.5
–1.6
–1.7
VDD = 2.50V
–1.8
–1.9
–2.0
–2.1
–2.2
–2.3
–2.4
–2.5
VDD = 2.25V
–2.6
–2.7
–2.8
–2.9
–3.0
TA = 25°C
10k
100k
1M
10M
100M
1G
10G
FREQUENCY (Hz)
Figure 7. Insertion Loss vs. Frequency over Supplies
(S12 and S21)
–0.3
–0.4
–0.5
–0.6
–0.7
–0.8
VDD = 2.75V
VDD = 2.50V
VDD = 2.25V
–0.9
–1.0 TA = 25°C
10k
100k
1M
10M
100M
1G
10G
FREQUENCY (Hz)
Figure 8. Insertion Loss vs. Frequency over Supplies
(S12 and S21) (Zoomed Figure 7)
–0.3
–0.4
–0.5
–0.6
–0.7
–0.8
–0.9
–1.0
VDD = 1.95V
–1.1
–1.2
–1.3
VDD = 1.80V
–1.4
–1.5
VDD = 1.65V
–1.6
–1.7
–1.8
–1.9
–2.0
–2.1
–2.2
–2.3
–2.4
–2.5
–2.6
–2.7
–2.8
–2.9
–3.0
TA = 25°C
10k
100k
1M
10M
100M
1G
10G
FREQUENCY (Hz)
Figure 9. Insertion Loss vs. Frequency over Supplies
(S12 and S21)
ADG936/ADG936-R
–0.3
–0.4
–0.5
–0.6
–0.7
–0.8
TA = –40°C
–0.9
–1.0
–1.1
–1.2
TA = +25°C
–1.3
–1.4
–1.5
–1.6
TA = +85°C
–1.7
–1.8
–1.9
–2.0
–2.1
–2.2
–2.3
–2.4
–2.5
–2.6
–2.7
–2.8
–2.9
–3.0
VDD = 2.5V
10k
100k
1M
10M
100M
1G
10G
FREQUENCY (Hz)
Figure 10. Insertion Loss vs. Frequency over Temperature
(S12 and S21)
–10
VDD = 1.65V TO 2.75V
TA = 25°C
–20
–30
–40
–50
S21
–60
–70
S12
–80
10k
100k
1M
10M
100M
1G
10G
FREQUENCY (Hz)
Figure 11. Isolation vs. Frequency over Supplies
–10
VDD = 2.5V
–20
–30
–40
–50
–60
TA = +85°C
–70
TA = +25°C
–80
–90
–100
–110
10k
100k
TA = –40°C
1M
10M
100M
1G
10G
FREQUENCY (Hz)
Figure 12. Isolation vs. Frequency over Temperature
Rev. B | Page 7 of 16