ADM2582E/ADM2587E
ADM2582E/ADM2587E REGULATORY INFORMATION
Table 5. ADM2582E/ADM2587E Approvals
Organization Approval Type
UL
Recognized under the Component
Recognition Program of Underwriters
Laboratories, Inc.
VDE
Certified according to DIN EN 60747-5-2
(VDE 0884 Part 2): 2003-01
Notes
In accordance with UL 1577, each ADM2582E/ADM2587E is proof tested
by applying an insulation test voltage ≥ 3000 V rms for 1 second.
In accordance with DIN EN 60747-5-2, each ADM2582E/ADM2587E is
proof tested by applying an insulation test voltage ≥ 1050 VPEAK for
1 second.
ADM2582E/ADM2587E INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
Symbol
L(I01)
L(I02)
CTI
Value
2500
7.7
7.6
0.017 min
>175
IIIa
Unit
V rms
mm
mm
mm
V
Conditions
1-minute duration
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance along body
Insulation distance through insulation
DIN IEC 112/VDE 0303-1
Material Group (DIN VDE 0110: 1989-01, Table 1)
ADM2582E/ADM2587E VDE 0884 INSULATION CHARACTERISTICS
This isolator is suitable for basic electrical isolation only within the safety limit data. Maintenance of the safety data must be ensured by
means of protective circuits.
An asterisk (*) on packages denotes VDE 0884 Part 2 approval.
Table 7.
Description
CLASSIFICATIONS
Installation Classification per DIN VDE 0110 for
Rated Mains Voltage
≤150 V rms
≤300 V rms
≤400 V rms
Climatic Classification
Pollution Degree
VOLTAGE
Maximum Working Insulation Voltage
Input-to-Output Test Voltage
Method b1
Method a
After Environmental Tests, Subgroup 1
After Input and/or Safety Test,
Subgroup 2/Subgroup 3
Highest Allowable Overvoltage
SAFETY-LIMITING VALUES
Case Temperature
Input Current
Output Current
Insulation Resistance at TS
Conditions
DIN VDE 0110, see Table 1
VIORM × 1.875 = VPR, 100% production tested,
tm = 1 sec, partial discharge < 5 pC
VIORM × 1.6 = VPR, tm = 60 sec, partial discharge < 5 pC
VIORM × 1.2 = VPR, tm = 60 sec, partial discharge < 5 pC
Transient overvoltage, tTR = 10 sec
Maximum value allowed in the event of a failure
VIO = 500 V
Symbol Characteristic Unit
VIORM
VPR
I to IV
I to III
I to II
40/85/21
2
560
1050
896
672
VTR
4000
TS
IS, INPUT
IS, OUTPUT
RS
150
265
335
>109
V peak
V peak
V peak
V peak
V peak
°C
mA
mA
Ω
Rev. C | Page 5 of 20