Test results and significant waveforms
AN3118
4.6
Power management and housekeeping functions
A special feature of the L6563H is that it facilitates the implementation of the “housekeeping”
circuitry needed to coordinate the operation of the PFC stage to that of the cascaded DC-
DC converter. The functions realized by the housekeeping circuitry ensure that transient
conditions like power-up or power-down sequencing or failures of either power stage be
properly handled. The L6563H provides some pins to do that.
As already mentioned, one communication line between the L6563H and the PWM
controller of the cascaded DC-DC converter is the PWM_LATCH pin (pin #8), which is
normally open when the PFC works properly. It goes high if the L6563H loses control of the
output voltage (because of a failure of the control loop) with the aim of also latching-off the
PWM controller of the cascaded DC-DC converter.
A second communication line can be established via the disable function included in the
RUN pin. Typically, this line is used to allow the PWM controller of the cascaded DC-DC
converter to shut down the L6563H in case of light load, to minimize the no-load input
consumption of the power supply.
Examples of intefacing some ST half-bridges controllers are shown in Figure 34.
Figure 34. L6563H on/off control by a cascaded converter controller via PFC_OK or
RUN pin