5 .Test
No change on display and in operation under the following test condition.
Conditions: Unless otherwise specified, tests will be conducted under the following condition.
T e m p e r a t u r e : 2 0 ±5 °C
Humidity
: 6 5 ±5 % R H
tests will be not conducted under functioning state.
No.
Parameter
Conditions
Notes
1
High Temperature
5 0 °C ±2 °C , 9 6 h r s ( o p e r a t i o n s t a t e )
2
Low Temperature
0 °C ±2 °C , 9 6 h r s ( o p e r a t i o n s t a t e )
1
3
H i g h T e m p e r a t u r e S t o r a g e 6 0 °C ±2 °C , 9 6 h r s
2
4
L o w T e m p e r a t u r e S t o r a g e - 2 0 °C ±2 °C , 9 6 h r s
1,2
5
Damp Proof Test
4 0 °C ±2 °C , 9 0 ~ 9 5 % R H , 9 6 h r s
1,2
6
Vibration Test
Total fixed amplitude : 1.5mm
3
Vibration Frequency : 10~55Hz
One cycle 60 seconds to 3 directions of X,
each 15 minutes
7
Shock Test
To be measured after dropping from 60cm
the concrete surface in packing state.
Dropping method corner dropping
F
A corner : once
E
GD
C
Edge dropping
B,C,D edge : once
B
A
Face dropping
60cm
E,F,G face : once
Concrete Surface
Note 1 :
Note 2 :
Note 3 :
No dew condensation to be observed.
The function test shall be conducted after 4 hours storage at the normal
Temperature and humidity after removed from the test chamber.
Vibration test will be conducted to the product itself without putting it in a
container.
F-51430NFU-FW-AA (AA) No. 2001-0115
OPTREX CORPORATION
Page 14/20