Qdatasheet_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

GL651USB View Datasheet(PDF) - Genesys Logic

Part Name
Description
MFG CO.
GL651USB
Genesys-Logic
Genesys Logic Genesys-Logic
'GL651USB' PDF : 16 Pages View PDF
Prev 11 12 13 14 15 16
GL651USB USB KEYBOARD HUB CONTROLLER
PT_LOW_SPD
PT_PWR
PT_RST
PT_OVCUR
PT_SUS
PT_EN
PT_CON
:1’b0 – full speed device connected, 1’b1 – low speed device
connected.
1’b0 – port is in power off state, 1’b1 – port is not in power
off state
:1’b0 – Reset signaling not asserted, 1b’1 – Reset signaling
asserted
: 1’b0 – No over-current condition occurred on this port
1’b1 – An over-current condition exists on this port
: 1’b0 – port not suspended, 1’b1 – port suspended or
resuming
: 1’b0 – port is disabled, 1’b1 – port is enabled
: 1’b0 – No device is present, 1’b1 – A device is present on
this port
BUS_PORT_DATA
( offset 11, default = 00h )
R/O
R/O
R/O
R/O
R/O
R/O
R/O
VP
VM
-- C_PT_RST C_PT_ C_PT_ C_PT_EN C_PT_
OVCUR
SUS
CON
Bus state and Port status change indicator:
VP
: VP state on the downstream port
VM
C_PT_RST
C_PT_OVCUR
: VM state on the downstream port
: 1’b0 – No change, 1’b1 – Reset complete
: 1’b0 – No change has occurred to over-current indicator
: 1’b1 – over-current indicator has changed
C_PT_SUS
: 1’b0 – No change, 1’b1: – Resume complete
C_PT_EN
: Set to one when a port is disabled because of a Port_error
condition
C_PT_CON
: 1’b0 – No change has occurred to current connect status
: 1’b1 – Current connect status has changed
HOST_CMD
( offset 12, default = 0Fh )
W/O
W/O
W/O
W/O
W/O
W/O
W/O
W/O
HB_CMD3 HB_CMD2 HB_CMD1 HB_CMD0 PT_CMD3 PT_CMD2 PT_CMD1 PT_CMD0
Host command to the hub:
PT_CMD3~0 : 4’h0 –SetPortFeature(PORT_SUSPEND)
: 4’h1 –SetPortFeature(PORT_RESET)
: 4’h2 –SetPortFeature(PORT_POWER)
: 4’h3 –ClearPortFeature(PORT_ENABLE)
: 4’h4 –ClearPortFeature(PORT_SUSPEND)
: 4’h5 –ClearPortFeature(PORT_POWER)
: 4’h6 –ClearPortFeature(C_PORT_RESET)
: 4’h7 –ClearPortFeature(C_PORT_OVER_CURRENT)
: 4’h8 –ClearPortFeature(C_PORT_SUSPEND)
: 4’h9 –ClearPortFeature(C_PORT_ENABLE)
: 4’hA –ClearPortFeature(C_PORT_CONNECTION)
HB_CMD3
HB_CMD2
HB_CMD1
HB_CMD0
: 1’b1 –SetHubFeature(C_HUB_LOCAL_POWER)
: 1’b1 –SetHubFeature(C_HUB_OVER_CURRENT)
: 1’b1 –ClearHubFeature(C_HUB_LOCAL_POWER)
: 1’b1 –ClearHubFeature(C_HUB_OVER_CURRENT)
ENP2_IND
--
( offset 13, default = 00h )
--
--
--
R/O
R/O
R/O
R/O
PT3
PT2
PT1
HUB
12