GL850A USB 2.0 Low-Power HUB Controller
RESET#
GANG_CTL
50ms
Input mode, strapping
to decide individual or
gang mode
Output mode, indicating
GL850A is in normal
mode or suspend mode
Figure 5.5 – Timing of PGANG/SUSPND strapping
DVDD(3.3V)
DVDD(3.3V)
GAND Mode
"0": Individual Mode
"1": GANG Mode
100K ohm
Suspend LED
Indicator
SUSPNDO
PGANG
GANG_CTL
Inside GL850A
On PCB
100K ohm
Suspend LED
Indicator
Individual
Mode
Figure 5.6 – GANG Mode Setting
5.2.3 SELF/BUS Power Setting
GL850A can operate under bus power and conform to the power consumption limitation completely
(suspend current < 2.5 mA, normal operation current < 100 mA). By setting PSELF, GL850A can be
configured as a bus-power or a self-power hub.
©2000-2007 Genesys Logic Inc. - All rights reserved.
Page 20