Prev 11 12 13 14 15
VCC = 5 V
II = 7.5 mA
II
tRISE
tFALL
300
RL = 4 k
290
60
RL = 1 k
40
20
RL = 350
0
RL = 350 Ω, 1 k, 4 k
-60 -40 -20 0 20 40 60 80 100
TA – TEMPERATURE – °C
Figure 12. Typical Rise and Fall Time
vs. Temperature.
1
B
2
A
3
VCC 8
7
6
+5 V
0.1 µF
BYPASS
350
OUTPUT VO
MONITORING
NODE
4
GND 5
VCM
+–
PULSE
GENERATOR
ZO = 50
VCM (PEAK)
VCM
0V
5 V SWITCH AT A: II = 0 mA
VO
VO (MIN.)
SWITCH AT B: II = 7.5 mA
VO 0.5 V
VO (MAX.)
CMH
CML
Figure 13. Test Circuit for Common Mode Transient Immunity and Typical
Waveforms.
5
VCC = 5.0 V
VO = 0.6 V
4
3
RL = 350
2
RL = 1 k
1
RL = 4 k
0
-60 -40 -20 0 20 40 60 80 100
TA – TEMPERATURE – °C
Figure 14. Typical Input Threshold
Current vs. Temperature.
VCC BUS (FRONT)
NC
NC
NC
NC
GND BUS (BACK)
0.1µF
0.1µF
10 mm MAX.
(SEE NOTE 1)
Figure 15. Recommended Printed Circuit Board Layout.
ENABLE
(IF USED)
OUTPUT 1
ENABLE
(IF USED)
OUTPUT 2
1-324