HFBR-5103 Series
Recommended Operating Conditions*
Parameter
Ambient Operating Temperature
Supply Voltage
Data Input Voltage - Low
Data Input Voltage - High
Data and Signal Detect Output Load
Symbol Min.
Typ. Max.
Unit
Reference
TA
0
70
°C
VCC
4.75
5.25
V
VIL - VCC -1.810
-1.475
V
VIH - VCC -1.165
-0.880
V
RL
50
Ω
Note 2
*Applies to HFBR-5103 &HFBR-5103T & HFBR-5103P/-5103PE Series except for HFBR-5103A/-5103AT. TA for
HFBR-5103A/-5103AT is -40°C and 85°C.
Transmitter Electrical Characteristics*
(TA = 0°C to 70°C, VCC = 4.75 V to 5.25 V)
Parameter
Symbol
Min.
Typ.
Max.
Supply Current
Power Dissipation
Data Input Current - Low
Data Input Current - High
ICC
PDISS
IIL
IIH
145
185
0.76
0.97
-350
0
14
350
*Applies to HFBR-5103 &HFBR 5103T & HFBR-5103P/-5103PE Series except for HFBR-5103A/-5103AT. TA for
HFBR-5103A/-5103AT is -40°C and 85°C..
Unit
Reference
mA
Note 3
W
µA
µA
Receiver Electrical Characteristics
(T = 0°C to 70°C, V = 4.75 V to 5.25 V)*
A
CC
Parameter
Symbol
Min. Typ. Max.
Unit
Supply Current
Power Dissipation
Data Output Voltage - Low
Data Output Voltage - High
Data Output Rise Time
Data Output Fall Time
Signal Detect Output Voltage - Low
Signal Detect Output Voltage - High
Signal Detect Output Rise Time
Signal Detect Output Fall Time
ICC
82
145
mA
PDISS
0.3
0.5
W
VOL - VCC
-1.840
-1.620
V
VOH - VCC
-1.045
-0.880
V
tr
0.35
2.2
ns
tf
0.35
2.2
ns
VOL - VCC
-1.840
-1.620
V
VOH - VCC
-1.045
-0.880
V
tr
0.35
2.2
ns
tf
0.35
2.2
ns
*Applies to HFBR-5103 &HFBR 5103T & HFBR-5103P and 5103PE Series except for HFBR-5103A/-5103AT. TA for
HFBR-5103A/-5103AT is -40°C and 85°C.
Reference
Note 4
Note 5
Note 6
Note 6
Note 7
Note 7
Note 6
Note 6
Note 7
Note 7
16