Qdatasheet_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

HPS35L-NNR-000 View Datasheet(PDF) - Emerson Network Power

Part Name
Description
MFG CO.
HPS35L-NNR-000
EMERSON-NETWORKPOWER
Emerson Network Power EMERSON-NETWORKPOWER
'HPS35L-NNR-000' PDF : 4 Pages View PDF
1 2 3 4
Embedded Power for
Business-Critical Continuity
HPS35 Series
350 - 1400 Watts
Total Power:
Input Voltage:
# of Outputs:
350 Watts
per module
90-264 VAC
Single and
standby
Special Features
• Active Power Factor Correction
• EN61000-3-2 compliant
• CISPR22, EN55022 Level-B
conducted/radiated EMI
• EN61000 immunity standards
• 5Vsb@2A
• Overvoltage protection (OVP)
• Overcurrent protection (OCP)
• Overtemperature protection
(OTP)
• AC OK signal and indicator LED
• DC OK signal and indicator LED
• Remote Inhibit
• Remote Sense on main output
• Hot Plug
• N+1 Redundant
• 2 year warranty
Safety
UL
CSA
TUV
CB
CE
UL60950-1, 1st Ed.
(April 1, 2003)
CSA C22.2 60950-1-03
EN60950-1:2001
(1st Ed.)
IEC60950-1,
1st Ed. (2001)
Mark (LVD)
Rev. 2.18.09_133
HPS35 Series
 of 4
Electrical Specifications
Input
Input voltage:
90-264 VAC typical
Frequency:
47-440 Hz
Inrush current:
40 A peak typical @ 25 °C
Efficiency:
80% typ @ full load, 230 VAC
Power factor:
0.98 typical @ 115 VAC, full load
Turn-on time:
AC ON -2 sec., Inhibit / Enable 160 ms
EMI filter standard:
CISPR 22, EN55022 Level “B”
Leakage current standard: <0.5 mA max @ 230 VAC @ 60Hz (per module)
Radiated EMI:
CISPR 22, EN55022 Level “B”
Holdup time:
20 ms minimum (independent of input VAC)
AC OK:
5 ms early warning minimum before outputs lose regulation
Harmonic distortion:
Meets EN61000-3-2
Isolation:
Meets EN60950
Output
Adjustability:
±5% of nominal output voltage
Overall regulation:
±3%
Ripple:
1% of Vout pk - pk (20 MHz bandwidth)
Dynamic response:
4% from 25% to 75% load step
Recovery time:
To within 1% in <300 µsec
Overcurrent protection: 115 - 130% of rated output current
Short circuit protection: Protected for continuous short circuit. Auto recovery.
Overvoltage protection: 120 - 140% AC Reset.
Reverse voltage protection: 100% of rated output voltage
Thermal protection:
Main and Aux disabled when internal temp exceeds
safe operating range
Remote sense:
Single wire parallel:
DC OK:
Up to 0.5 V total drop
Current share to within 10% of total rated current on
main output
±5% of nominal
Share Link: GO URL