HT66F016/HT66F017/HT68F016/HT68F017
HT66F016R/HT66F017R/HT68F016R/HT68F017R
Symbol
Parameter
VLVR1
VLVR2
VLVR3
LVR Voltage Level
Test Conditions
VDD
Conditions
LVR Enable, 2.10V option
LVR Enable, 2.55V option
¾
LVR Enable, 3.15V option
VLVR4
LVR Enable, 3.80V option
VLVD1
VLVD2
VLVD3
VLVD4
VLVD5
LVD Voltage Level
LVDEN=1, VLVD=2.0V
LVDEN=1, VLVD=2.2V
LVDEN=1, VLVD=2.4V
LVDEN=1, VLVD=2.7V
¾
LVDEN=1, VLVD=3.0V
VLVD6
LVDEN=1, VLVD=3.3V
VLVD7
VLVD8
ILVD1
ILVD2
LVDEN=1, VLVD=3.6V
LVDEN=1, VLVD=4.0V
Additional Power Consumption
if LVR and LVD is Used
¾
LVR disable, LVDEN=1
LVR enable, LVDEN=1
3V IOL=9mA
VOL
Output Low Voltage I/O Port
5V IOL=20mA
VOH
Output High Voltage I/O Port
3V IOH=-3.2mA
5V IOH=-7.4mA
RPH
Pull-high Resistance for I/O
Ports
3V
5V
¾
V125
1.25V Reference with Buffer
Voltage
¾
¾
Additional Power Consumption
I125
if 1.25V Reference with Buffer is ¾
¾
used
Min.
-5%
-5%
-5%
-5%
-5%
-5%
-5%
-5%
-5%
-5%
-5%
-5%
¾
¾
¾
¾
2.7
4.5
20
10
-3%
¾
Typ.
2.10
2.55
3.15
3.80
2.00
2.20
2.40
2.70
3.00
3.30
3.60
4.00
75
90
¾
¾
¾
¾
60
30
1.25
200
Ta=25°C
Max. Unit
+5%
V
+5%
V
+5%
V
+5%
V
+5%
V
+5%
V
+5%
V
+5%
V
+5%
V
+5%
V
+5%
V
+5%
V
120
mA
150
mA
0.3
V
0.5
V
¾
V
¾
V
100
kW
50
kW
+3%
V
300
mA
Rev. 1.40
13