Clocks Transmit Clock Tolerance
ICS1889
T#
PARAMETER (conditions)
t1
TXCLK Duty Cycle
t2
TXCLK Period
Note: TXCLK Duty Cycle = REF_IN Duty Cycle ± 5%.
MIN
35
—
Clocks Receive Clock Behavior
TYP
MAX
UNITS
50
65
%
40
—
ns
T#
PARAMETER (conditions)
MIN
t 1 RXCLK Duty Cycle
45
t 2 RTXCLK Period
—
t3
RXDV De-asserted Recovered Clock to Nominal
Clock Cycle Extension (No Extension)
—
t4
RXDV De-asserted Nominal Clock to Recovered
Clock Cycle Extension
—
TYP
MAX
UNITS
50
55
%
40
—
ns
—
—
—
—
60
ns
27