IS62LV256
OPERATING RANGE
Range
Ambient Temperature
Commercial
0°C to +70°C
Industrial
–40°C to +85°C
VCC
3.3V ± 5%
3.3V ± 5%
DC ELECTRICAL CHARACTERISTICS (Over Operating Range)
Symbol Parameter
Test Conditions
Min.
Max.
Unit
VOH
Output HIGH Voltage VCC = Min., IOH = –1.0 mA
2.4
—
V
VOL
Output LOW Voltage VCC = Min., IOL = 2.1 mA
—
0.4
V
VIH
Input HIGH Voltage
VIL
Input LOW Voltage(1)
2.2 VCC + 0.3 V
–0.3
0.8
V
ILI
Input Leakage
GND < VIN < VCC
Com. –2
2
µA
Ind. –5
5
ILO
Output Leakage
GND < VOUT < VCC, Outputs Disabled Com. –2
2
µA
Ind. –5
5
Notes:
1. VIL = –3.0V for pulse width less than 10 ns.
2. Not more than one output should be shorted at one time. Duration of the short circuit should not exceed 30 seconds.
POWER SUPPLY CHARACTERISTICS(1) (Over Operating Range)
Symbol Parameter
ICC1 Vcc Operating
Supply Current
ICC2 Vcc Dynamic Operating
Supply Current
Test Conditions
VCC = Max., CE = VIL
IOUT = 0 mA, f = 0
VCC = Max., CE = VIL
IOUT = 0 mA, f = fMAX
-45 ns
Min. Max.
Com. — 20
Ind. — 30
Com. — 35
Ind. — 45
-70 ns
Min. Max.
— 20
— 30
— 30
— 40
-100 ns
Min. Max. Unit
— 20 mA
— 30
— 30 mA
— 40
ISB1 TTL Standby Current
(TTL Inputs)
VCC = Max.,
VIN = VIH or VIL
CE > VIH, f = 0
Com. — 2
Ind. — 5
—2
—5
— 2 mA
—5
ISB2 CMOS Standby
VCC = Max.,
Current (CMOS Inputs) CE > VCC – 0.2V,
VIN > VCC – 0.2V, or
VIN < 0.2V, f = 0
Com. — 90
Ind. — 200
— 90
— 200
— 90 µA
— 200
Notes:
1. At f = fMAX, address and data inputs are cycling at the maximum frequency, f = 0 means no input lines change.
CAPACITANCE(1,2)
Symbol
Parameter
Conditions
Max.
Unit
CIN
Input Capacitance
VIN = 0V
6
pF
COUT
Output Capacitance
VOUT = 0V
5
pF
Notes:
1. Tested initially and after any design or process changes that may affect these parameters.
2. Test conditions: TA = 25°C, f = 1 MHz, Vcc =3.3V.
Integrated Circuit Solution Inc.
3
SR006-0B