Set Default Associated Data (OP Code: 0007h):
The value in WR0-1 is set as the default associated data, which is output when a miss
hit occurs. Upon completion of the data input to the internal register, bit3 of STAT0
will be changed to ‘1,’ and CCMPN to Low.
WR1
WR0
1
0 15
0
Default Associate Data (17-16) Default Associated Data ( 15 - 0)
Read Default Associated Data (OP code: 0017h):
The Default Associate Data is written to RR0-1.
Upon completion of the data setting to RR0-1, bit3 of STAT0 (Command Complete)
will be changed to ‘1,’ and CCMPN to Low.
RR1
RR0
1
0 15
0
Default Associate Data (17-16) Default Associate Data ( 15 – 0)